UL XHHW-2 | Single Conductor (600/1000V)
For use in open wiring and raceways (with the exception of cable troughs and ventilated flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum conductor temperature 90°C.
Construction
Voltage
600V, 1000V (optional)
Product Construction
- Insulation:
- FR XLPE (XHHW-2 / VW-1 rated) (standard) rated: 90°C wet / dry
- FR XLPE (RHW-2 rated) (optional)
- Available in:
- All colours
Certifications
Certifications/Compliances
- UL 44, Thermoset Insulated Wires and Cables
- Gasoline Resistant GR I and II
- Oil Resistant PR I and II
- – 40°C cold impact rated
- – 40°C cold bend rated
Colour Coding
- Black conductor (standard)
Properties
- Strand Bare (ASTM B8) Annealed Copper Conductors
- FR XLPE (XHHW-2 / VW-1 Rated) Insulated Conductor
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Insulation Thickness (in/mm) | Cable Weight (lbs/1000ft)/ (kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/kg) | Min. Bend Radius (Pull) (in/mm) |
1V010U14010BN00 | 1 | 14 | 0.03 / 0.76 | 18 / 27 | 35 | 33 / 15 | 1.2 / 30 |
1V010U12010BN00 | 1 | 12 | 0.03 / 0.76 | 27 / 40 | 40 | 52 / 24 | 1.4 / 35 |
1V010U10010BN00 | 1 | 10 | 0.03 / 0.76 | 40 / 59 | 55 | 83 / 38 | 1.6 / 40 |
1V010U08010BN00 | 1 | 8 | 0.045 / 1.14 | 68 / 101 | 80 | 132 / 60 | 2.1 / 54 |
1V010U06010BN00 | 1 | 6 | 0.045 / 1.14 | 101 / 151 | 105 | 210 / 95 | 2.4 / 62 |
1V010U04010BN00 | 1 | 4 | 0.045 / 1.14 | 154 / 230 | 140 | 334 / 151 | 2.9 / 73 |
1V010U02010BN00 | 1 | 2 | 0.045 / 1.14 | 237 / 352 | 190 | 531 / 241 | 3.4 / 86 |
1V010U01014BN00 | 1 | 1 | 0.055 / 1.4 | 300 / 447 | 220 | 670 / 304 | 3.9 / 100 |
1V010U1/014BN00 | 1 | 1/0 | 0.055 / 1.4 | 374 / 556 | 260 | 845 / 383 | 4.3 / 109 |
1V010U2/014BN00 | 1 | 2/0 | 0.055 / 1.4 | 464 / 691 | 300 | 1065 / 483 | 4.7 / 119 |
1V010U3/014BN00 | 1 | 3/0 | 0.055 / 1.4 | 579 / 861 | 350 | 1336 / 606 | 5.1 / 130 |
1V010U4/014BN00 | 1 | 4/0 | 0.055 / 1.4 | 722 / 1074 | 405 | 1693 / 768 | 5.6 / 143 |
1V010U25016BN00 | 1 | 250 | 0.065 / 1.65 | 845 / 1257 | 455 | 2000 / 907 | 6.2 / 158 |
1V010U35016BN00 | 1 | 350 | 0.065 / 1.65 | 1166 / 1735 | 570 | 2800 / 1270 | 7.2 / 182 |
1V010U50016BN00 | 1 | 500 | 0.065 / 1.65 | 1644 / 2446 | 700 | 4000 / 1814 | 8.3 / 211 |
1V010U75016BN00 | 1 | 750 | 0.08 / 2.03 | 2466 / 3670 | 885 | 6000 / 2722 | 10.2 / 259 |
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(17). Values are corrected according to Table 310.15(B)(17) for number of Conductors.
Markets / Applications
- Generation – Renewables – Wind
- Transit
- Water/Waste Water Treatment
- Generation – Traditional Power
- Generation
- Communication Power & Control
- Generation – Nuclear
- Power Distribution
- Civil Construction Projects
- Power Distribution – LV
- Industrial
- Generation – Renewables
- Petrochem/Pulp & Paper
- Utility
- Commercial Construction Projects
- OIl & Gas
- Generation – Renewables – Geo Thermal
- Generation – Renewables – Solar
- Mining
Voltage
600V, 1000V (optional)
Product Construction
- Insulation:
- FR XLPE (XHHW-2 / VW-1 rated) (standard) rated: 90°C wet / dry
- FR XLPE (RHW-2 rated) (optional)
- Available in:
- All colours
Certifications/Compliances
- UL 44, Thermoset Insulated Wires and Cables
- Gasoline Resistant GR I and II
- Oil Resistant PR I and II
- – 40°C cold impact rated
- – 40°C cold bend rated
Colour Coding
- Black conductor (standard)
- Strand Bare (ASTM B8) Annealed Copper Conductors
- FR XLPE (XHHW-2 / VW-1 Rated) Insulated Conductor
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Insulation Thickness (in/mm) | Cable Weight (lbs/1000ft)/ (kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/kg) | Min. Bend Radius (Pull) (in/mm) |
1V010U14010BN00 | 1 | 14 | 0.03 / 0.76 | 18 / 27 | 35 | 33 / 15 | 1.2 / 30 |
1V010U12010BN00 | 1 | 12 | 0.03 / 0.76 | 27 / 40 | 40 | 52 / 24 | 1.4 / 35 |
1V010U10010BN00 | 1 | 10 | 0.03 / 0.76 | 40 / 59 | 55 | 83 / 38 | 1.6 / 40 |
1V010U08010BN00 | 1 | 8 | 0.045 / 1.14 | 68 / 101 | 80 | 132 / 60 | 2.1 / 54 |
1V010U06010BN00 | 1 | 6 | 0.045 / 1.14 | 101 / 151 | 105 | 210 / 95 | 2.4 / 62 |
1V010U04010BN00 | 1 | 4 | 0.045 / 1.14 | 154 / 230 | 140 | 334 / 151 | 2.9 / 73 |
1V010U02010BN00 | 1 | 2 | 0.045 / 1.14 | 237 / 352 | 190 | 531 / 241 | 3.4 / 86 |
1V010U01014BN00 | 1 | 1 | 0.055 / 1.4 | 300 / 447 | 220 | 670 / 304 | 3.9 / 100 |
1V010U1/014BN00 | 1 | 1/0 | 0.055 / 1.4 | 374 / 556 | 260 | 845 / 383 | 4.3 / 109 |
1V010U2/014BN00 | 1 | 2/0 | 0.055 / 1.4 | 464 / 691 | 300 | 1065 / 483 | 4.7 / 119 |
1V010U3/014BN00 | 1 | 3/0 | 0.055 / 1.4 | 579 / 861 | 350 | 1336 / 606 | 5.1 / 130 |
1V010U4/014BN00 | 1 | 4/0 | 0.055 / 1.4 | 722 / 1074 | 405 | 1693 / 768 | 5.6 / 143 |
1V010U25016BN00 | 1 | 250 | 0.065 / 1.65 | 845 / 1257 | 455 | 2000 / 907 | 6.2 / 158 |
1V010U35016BN00 | 1 | 350 | 0.065 / 1.65 | 1166 / 1735 | 570 | 2800 / 1270 | 7.2 / 182 |
1V010U50016BN00 | 1 | 500 | 0.065 / 1.65 | 1644 / 2446 | 700 | 4000 / 1814 | 8.3 / 211 |
1V010U75016BN00 | 1 | 750 | 0.08 / 2.03 | 2466 / 3670 | 885 | 6000 / 2722 | 10.2 / 259 |
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(17). Values are corrected according to Table 310.15(B)(17) for number of Conductors.
- Generation – Renewables – Wind
- Transit
- Water/Waste Water Treatment
- Generation – Traditional Power
- Generation
- Communication Power & Control
- Generation – Nuclear
- Power Distribution
- Civil Construction Projects
- Power Distribution – LV
- Industrial
- Generation – Renewables
- Petrochem/Pulp & Paper
- Utility
- Commercial Construction Projects
- OIl & Gas
- Generation – Renewables – Geo Thermal
- Generation – Renewables – Solar
- Mining