UL HD-XHHW-2 | Single Conductor (600V)
Heavy Duty provides an extra level of reliability and is suitable for use in ventilated, non- ventilated and ladder type cable trays, direct burial and raceways. Applicable for use in Utilities, Industrial and Commercial applications.
Construction
Voltage
600V
Optional: 2000V
Product Construction
- Insulation:
- EPR (XHHW-2 rated)rated: 90°C wet / dry
- Jacket:
- Thermoplastic CPE black outer jacket (standard) rated: 90°C
- Thermoset CPE (optional)
- Available in:
- Custom insulation / jacket colours
Certifications
Certifications/Compliances
- UL 44, Thermoset Insulated Wires and Cables 1 2 3
- UL 1685 / FT4, Vertical Tray Flame Test rated
- IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- UV sunlight resistant SUN RES (all colours)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 20, 21 (Div 1)
- Class II Zone 22 (Div 2)
Colour Coding
- Black conductor (standard)
Properties
- High Strand Bare Copper Conductors (Tinned Available)
- Ethylene Propylene Rubber (EPR) (XHHW-2 Rated) Insulated Conductor
- Thermoset CPE Protective Jacket
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Nominal Diameter Overall Cable (in/mm) | Cable Weight(lbs/1000ft)/ (kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/kg) | Min. Bend Radius (Pull) (in/mm) |
4M010U140100400 | 1 | 14 | 0.175 / 4.45 | 25 / 37 | 25 | 33 / 15 | 1.6 / 40 |
4M010U120100400 | 1 | 12 | 0.193 / 4.9 | 34 / 51 | 30 | 52 / 24 | 1.7 / 44 |
4M010U100100400 | 1 | 10 | 0.218 / 5.54 | 48 / 72 | 40 | 83 / 38 | 2 / 50 |
4M010U080100400 | 1 | 8 | 0.307 / 7.8 | 87 / 129 | 55 | 132 / 60 | 2.8 / 70 |
4M010U060100400 | 1 | 6 | 0.344 / 8.74 | 123 / 183 | 75 | 210 / 95 | 3.1 / 79 |
4M010U040100400 | 1 | 4 | 0.391 / 9.93 | 179 / 267 | 95 | 334 / 151 | 3.5 / 89 |
4M010U030100400 | 1 | 3 | 0.418 / 10.62 | 218 / 324 | 115 | 421 / 191 | 3.8 / 96 |
4M010U020100400 | 1 | 2 | 0.449 / 11.4 | 266 / 396 | 130 | 531 / 241 | 4 / 103 |
4M010U010140400 | 1 | 1 | 0.538 / 13.67 | 349 / 519 | 145 | 670 / 304 | 4.8 / 123 |
4M010U1/0140400 | 1 | 1/0 | 0.578 / 14.68 | 426 / 634 | 170 | 845 / 383 | 5.2 / 132 |
4M010U2/0140400 | 1 | 2/0 | 0.621 / 15.77 | 521 / 776 | 195 | 1065 / 483 | 5.6 / 142 |
4M010U3/0140400 | 1 | 3/0 | 0.672 / 17.07 | 641 / 954 | 225 | 1336 / 606 | 6 / 154 |
4M010U4/0140400 | 1 | 4/0 | 0.728 / 18.49 | 790 / 1175 | 260 | 1693 / 768 | 6.6 / 166 |
4M010U250160400 | 1 | 250 | 0.834 / 21.18 | 962 / 1432 | 290 | 2000 / 907 | 7.5 / 191 |
4M010U300160400 | 1 | 300 | 0.887 / 22.53 | 1132 / 1685 | 320 | 2400 / 1089 | 8 / 203 |
4M010U350160400 | 1 | 350 | 0.937 / 23.8 | 1302 / 1938 | 350 | 2800 / 1270 | 8.4 / 214 |
4M010U500160400 | 1 | 500 | 1.065 / 27.05 | 1805 / 2686 | 430 | 4000 / 1814 | 9.6 / 243 |
4M010U750160400 | 1 | 750 | 1.274 / 32.36 | 2669 / 3972 | 535 | 6000 / 2722 | 11.5 / 291 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16.
Markets / Applications
- Generation – Renewables – Wind
- Transit
- Water/Waste Water Treatment
- Generation – Traditional Power
- Generation
- Communication Power & Control
- Generation – Nuclear
- Power Distribution
- Industrial Construction/Automation
- Civil Construction Projects
- Power Distribution – LV
- Industrial
- Generation – Renewables
- Petrochem/Pulp & Paper
- Utility
- Commercial Construction Projects
- Generation – Renewables – Geo Thermal
- Generation – Renewables – Solar
- Mining
Voltage
600V
Optional: 2000V
Product Construction
- Insulation:
- EPR (XHHW-2 rated)rated: 90°C wet / dry
- Jacket:
- Thermoplastic CPE black outer jacket (standard) rated: 90°C
- Thermoset CPE (optional)
- Available in:
- Custom insulation / jacket colours
Certifications/Compliances
- UL 44, Thermoset Insulated Wires and Cables 1 2 3
- UL 1685 / FT4, Vertical Tray Flame Test rated
- IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- UV sunlight resistant SUN RES (all colours)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 20, 21 (Div 1)
- Class II Zone 22 (Div 2)
Colour Coding
- Black conductor (standard)
- High Strand Bare Copper Conductors (Tinned Available)
- Ethylene Propylene Rubber (EPR) (XHHW-2 Rated) Insulated Conductor
- Thermoset CPE Protective Jacket
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Nominal Diameter Overall Cable (in/mm) | Cable Weight(lbs/1000ft)/ (kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/kg) | Min. Bend Radius (Pull) (in/mm) |
4M010U140100400 | 1 | 14 | 0.175 / 4.45 | 25 / 37 | 25 | 33 / 15 | 1.6 / 40 |
4M010U120100400 | 1 | 12 | 0.193 / 4.9 | 34 / 51 | 30 | 52 / 24 | 1.7 / 44 |
4M010U100100400 | 1 | 10 | 0.218 / 5.54 | 48 / 72 | 40 | 83 / 38 | 2 / 50 |
4M010U080100400 | 1 | 8 | 0.307 / 7.8 | 87 / 129 | 55 | 132 / 60 | 2.8 / 70 |
4M010U060100400 | 1 | 6 | 0.344 / 8.74 | 123 / 183 | 75 | 210 / 95 | 3.1 / 79 |
4M010U040100400 | 1 | 4 | 0.391 / 9.93 | 179 / 267 | 95 | 334 / 151 | 3.5 / 89 |
4M010U030100400 | 1 | 3 | 0.418 / 10.62 | 218 / 324 | 115 | 421 / 191 | 3.8 / 96 |
4M010U020100400 | 1 | 2 | 0.449 / 11.4 | 266 / 396 | 130 | 531 / 241 | 4 / 103 |
4M010U010140400 | 1 | 1 | 0.538 / 13.67 | 349 / 519 | 145 | 670 / 304 | 4.8 / 123 |
4M010U1/0140400 | 1 | 1/0 | 0.578 / 14.68 | 426 / 634 | 170 | 845 / 383 | 5.2 / 132 |
4M010U2/0140400 | 1 | 2/0 | 0.621 / 15.77 | 521 / 776 | 195 | 1065 / 483 | 5.6 / 142 |
4M010U3/0140400 | 1 | 3/0 | 0.672 / 17.07 | 641 / 954 | 225 | 1336 / 606 | 6 / 154 |
4M010U4/0140400 | 1 | 4/0 | 0.728 / 18.49 | 790 / 1175 | 260 | 1693 / 768 | 6.6 / 166 |
4M010U250160400 | 1 | 250 | 0.834 / 21.18 | 962 / 1432 | 290 | 2000 / 907 | 7.5 / 191 |
4M010U300160400 | 1 | 300 | 0.887 / 22.53 | 1132 / 1685 | 320 | 2400 / 1089 | 8 / 203 |
4M010U350160400 | 1 | 350 | 0.937 / 23.8 | 1302 / 1938 | 350 | 2800 / 1270 | 8.4 / 214 |
4M010U500160400 | 1 | 500 | 1.065 / 27.05 | 1805 / 2686 | 430 | 4000 / 1814 | 9.6 / 243 |
4M010U750160400 | 1 | 750 | 1.274 / 32.36 | 2669 / 3972 | 535 | 6000 / 2722 | 11.5 / 291 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16.
- Generation – Renewables – Wind
- Transit
- Water/Waste Water Treatment
- Generation – Traditional Power
- Generation
- Communication Power & Control
- Generation – Nuclear
- Power Distribution
- Industrial Construction/Automation
- Civil Construction Projects
- Power Distribution – LV
- Industrial
- Generation – Renewables
- Petrochem/Pulp & Paper
- Utility
- Commercial Construction Projects
- Generation – Renewables – Geo Thermal
- Generation – Renewables – Solar
- Mining