Construction
Voltage
600/1000V (optional)
Product Construction
- Insulation:
- FR XLPE (XHHW-2 rated) rated: 90°C wet / dry
- VW-1 rated (optional)
- Armor:
- Aluminum Interlocked Armor (AIA) (standard)
- Steel Interlocked Armor (SIA) (optional)
- Jacket:
- FR PVC outer black jacket rated: 90°C to -40°C
- Thermoset CPE optional)
- Thermoplastic CPE (optional)
- Thermoplastic LSZH (optional)
- Available in:
- Custom insulation / jacket colours
- Composite constructions
- Inner jacket (optional)
Colour Coding
- Method1 K1 or K2 (standard)
- Method 4 (optional)
Certifications
Certifications/Compliances
- UL 1569, Metal Clad Cables (MC)
- UL 44, Thermoset Insulated Wires and Cables
- UL 1685 / FT4, Vertical Tray Flame Test rated IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- UV sunlight resistant SUN RES (all colours) (for CT use)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 22 (Div 2)
Properties
|
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Ground Wire Size (AWG/MCM) | Nominal Diameter Over Armor | Nominal Diameter Overall Cable (in/mm) | Cable Weight (lbs/1000ft)/(kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/ kg) | Min. Bend Radius (Pull) (in/mm) |
2C610U140200709 | 2 | 14 | 14 | 0.51 / 12.95 | 0.622 / 15.8 | 172 / 256 | 25 | 66 / 30 | 11.2 / 284 |
2C610U140300709 | 3 | 14 | 14 | 0.541 / 13.73 | 0.653 / 16.58 | 192 / 285 | 25 | 99 / 45 | 11.7 / 298 |
2C610U140400709 | 4 | 14 | 14 | 0.574 / 14.58 | 0.686 / 17.42 | 217 / 323 | 20 | 132 / 60 | 12.3 / 314 |
2C610U140500709 | 5 | 14 | 14 | 0.603 / 15.32 | 0.715 / 18.16 | 242 / 361 | 20 | 165 / 75 | 12.9 / 327 |
2C610U140600709 | 6 | 14 | 14 | 0.643 / 16.33 | 0.755 / 19.18 | 271 / 404 | 20 | 197 / 90 | 13.6 / 345 |
2C610U140700709 | 7 | 14 | 14 | 0.683 / 17.35 | 0.795 / 20.19 | 301 / 447 | 17.5 | 230 / 104 | 14.3 / 363 |
2C610U140800709 | 8 | 14 | 14 | 0.724 / 18.39 | 0.836 / 21.24 | 330 / 492 | 17.5 | 263 / 119 | 15 / 382 |
2C610U141000709 | 10 | 14 | 14 | 0.776 / 19.71 | 0.888 / 22.56 | 375 / 558 | 12.5 | 329 / 149 | 16 / 406 |
2C610U141200709 | 12 | 14 | 14 | 0.796 / 20.22 | 0.908 / 23.06 | 412 / 613 | 12.5 | 395 / 179 | 16.3 / 415 |
2C610U141400709 | 14 | 14 | 14 | 0.831 / 21.09 | 0.942 / 23.94 | 457 / 681 | 12.5 | 461 / 209 | 17 / 431 |
2C610U141500709 | 15 | 14 | 14 | 0.849 / 21.57 | 0.961 / 24.41 | 479 / 713 | 12.5 | 494 / 224 | 17.3 / 439 |
2C610U142000709 | 20 | 14 | 14 | 0.949 / 24.1 | 1.061 / 26.95 | 590 / 879 | 12.5 | 658 / 298 | 19.1 / 485 |
2C610U142500709 | 25 | 14 | 14 | 1.006 / 25.55 | 1.118 / 28.4 | 696 / 1036 | 11.25 | 823 / 373 | 20.1 / 511 |
2C610U143000709 | 30 | 14 | 14 | 1.06 / 26.94 | 1.173 / 29.78 | 792 / 1178 | 11.25 | 987 / 448 | 21.1 / 536 |
2C610U144000709 | 40 | 14 | 14 | 1.179 / 29.94 | 1.291 / 32.79 | 997 / 1484 | 10 | 1316 / 597 | 23.2 / 590 |
2C610U145000709 | 50 | 14 | 14 | 1.304 / 33.12 | 1.416 / 35.96 | 1198 / 1783 | 8.75 | 1645 / 746 | 25.5 / 647 |
2C610U120200709 | 2 | 12 | 12 | 0.546 / 13.87 | 0.658 / 16.71 | 206 / 306 | 30 | 104 / 47 | 11.8 / 301 |
2C610U120300709 | 3 | 12 | 12 | 0.581 / 14.75 | 0.693 / 17.6 | 234 / 348 | 30 | 157 / 71 | 12.5 / 317 |
2C610U120400709 | 4 | 12 | 12 | 0.618 / 15.71 | 0.73 / 18.55 | 269 / 400 | 24 | 209 / 95 | 13.1 / 334 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16. Values are corrected according to Table 310.15(C)(1) for number of Conductors.
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Ground Wire Size (AWG/MCM) | Nominal Diameter Over Armor | Nominal Diameter Overall Cable (in/mm) | Cable Weight (lbs/1000ft)/(kg/km) | Ampacity (30°C ambient) | Max.PullingTension (PullingEye)(lb/kg) | Min. Bend Radius (Pull) (in/mm) |
2C610U120500709 | 5 | 12 | 12 | 0.652 / 16.55 | 0.764 / 19.4 | 304 / 453 | 24 | 261 / 118 | 13.7 / 349 |
2C610U120600709 | 6 | 12 | 12 | 0.697 / 17.7 | 0.809 / 20.55 | 344 / 511 | 24 | 313 / 142 | 14.6 / 370 |
2C610U120700709 | 7 | 12 | 12 | 0.742 / 18.85 | 0.854 / 21.7 | 382 / 569 | 21 | 365 / 166 | 15.4 / 391 |
2C610U120800709 | 8 | 12 | 12 | 0.789 / 20.04 | 0.901 / 22.89 | 423 / 630 | 21 | 418 / 189 | 16.2 / 412 |
2C610U121000709 | 10 | 12 | 12 | 0.848 / 21.54 | 0.96 / 24.38 | 486 / 723 | 15 | 522 / 237 | 17.3 / 439 |
2C610U121200709 | 12 | 12 | 12 | 0.871 / 22.12 | 0.983 / 24.96 | 541 / 805 | 15 | 626 / 284 | 17.7 / 449 |
2C610U121400709 | 14 | 12 | 12 | 0.91 / 23.11 | 1.022 / 25.96 | 602 / 896 | 15 | 731 / 331 | 18.4 / 467 |
2C610U121500709 | 15 | 12 | 12 | 0.931 / 23.65 | 1.043 / 26.49 | 633 / 942 | 15 | 783 / 355 | 18.8 / 477 |
2C610U122000709 | 20 | 12 | 12 | 1.008 / 25.61 | 1.12 / 28.46 | 784 / 1166 | 15 | 1044 / 474 | 20.2 / 512 |
2C610U122500709 | 25 | 12 | 12 | 1.114 / 28.3 | 1.226 / 31.14 | 944 / 1404 | 13.5 | 1305 / 592 | 22.1 / 561 |
2C610U123000709 | 30 | 12 | 12 | 1.176 / 29.87 | 1.288 / 32.71 | 1081 / 1608 | 13.5 | 1566 / 710 | 23.2 / 589 |
2C610U124000709 | 40 | 12 | 12 | 1.31 / 33.28 | 1.422 / 36.13 | 1375 / 2047 | 12 | 2088 / 947 | 25.6 / 650 |
2C610U125000709 | 50 | 12 | 12 | 1.452 / 36.89 | 1.564 / 39.73 | 1664 / 2476 | 10.5 | 2610 / 1184 | 28.2 / 715 |
2C610U100200709 | 2 | 10 | 10 | 0.596 / 15.14 | 0.708 / 17.98 | 258 / 383 | 40 | 166 / 75 | 12.7 / 324 |
2C610U100300709 | 3 | 10 | 10 | 0.637 / 16.17 | 0.748 / 19.01 | 304 / 453 | 40 | 249 / 113 | 13.5 / 342 |
2C610U100400709 | 4 | 10 | 10 | 0.68 / 17.28 | 0.792 / 20.13 | 349 / 520 | 32 | 332 / 151 | 14.3 / 362 |
2C610U100500709 | 5 | 10 | 10 | 0.719 / 18.27 | 0.831 / 21.11 | 398 / 593 | 32 | 415 / 188 | 15 / 380 |
2C610U100600709 | 6 | 10 | 10 | 0.772 / 19.61 | 0.884 / 22.45 | 454 / 675 | 32 | 498 / 226 | 15.9 / 404 |
2C610U100700709 | 7 | 10 | 10 | 0.825 / 20.95 | 0.937 / 23.79 | 509 / 757 | 28 | 581 / 264 | 16.9 / 428 |
2C610U100800709 | 8 | 10 | 10 | 0.879 / 22.33 | 0.991 / 25.18 | 567 / 843 | 28 | 664 / 301 | 17.8 / 453 |
2C610U101000709 | 10 | 10 | 10 | 0.948 / 24.08 | 1.06 / 26.92 | 655 / 975 | 20 | 830 / 376 | 19.1 / 485 |
2C610U101200709 | 12 | 10 | 10 | 0.974 / 24.75 | 1.086 / 27.59 | 738 / 1098 | 20 | 996 / 452 | 19.6 / 497 |
2C610U101400709 | 14 | 10 | 10 | 0.984 / 25 | 1.096 / 27.84 | 823 / 1225 | 20 | 1162 / 527 | 19.7 / 501 |
2C610U101500709 | 15 | 10 | 10 | 1.009 / 25.62 | 1.121 / 28.47 | 868 / 1291 | 20 | 1245 / 565 | 20.2 / 512 |
2C610U102000709 | 20 | 10 | 10 | 1.141 / 28.98 | 1.253 / 31.82 | 1094 / 1628 | 20 | 1660 / 753 | 22.6 / 573 |
2C610U102500709 | 25 | 10 | 10 | 1.264 / 32.11 | 1.376 / 34.95 | 1325 / 1972 | 18 | 2075 / 941 | 24.8 / 629 |
2C610U103000709 | 30 | 10 | 10 | 1.336 / 33.94 | 1.448 / 36.78 | 1532 / 2279 | 18 | 2490 / 1129 | 26.1 / 662 |
2C610U104000709 | 40 | 10 | 10 | 1.493 / 37.92 | 1.605 / 40.76 | 1964 / 2923 | 16 | 3320 / 1506 | 28.9 / 734 |
2C610U105000709 | 50 | 10 | 10 | 1.658 / 42.12 | 1.79 / 45.47 | 2424 / 3607 | 14 | 4150 / 1882 | 32.2 / 819 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16. Values are corrected according to Table 310.15(C)(1) for number of Conductors.
Markets / Applications
|
|
Voltage
600/1000V (optional)
Product Construction
- Insulation:
- FR XLPE (XHHW-2 rated) rated: 90°C wet / dry
- VW-1 rated (optional)
- Armor:
- Aluminum Interlocked Armor (AIA) (standard)
- Steel Interlocked Armor (SIA) (optional)
- Jacket:
- FR PVC outer black jacket rated: 90°C to -40°C
- Thermoset CPE optional)
- Thermoplastic CPE (optional)
- Thermoplastic LSZH (optional)
- Available in:
- Custom insulation / jacket colours
- Composite constructions
- Inner jacket (optional)
Colour Coding
- Method1 K1 or K2 (standard)
- Method 4 (optional)
Certifications/Compliances
- UL 1569, Metal Clad Cables (MC)
- UL 44, Thermoset Insulated Wires and Cables
- UL 1685 / FT4, Vertical Tray Flame Test rated IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- UV sunlight resistant SUN RES (all colours) (for CT use)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 22 (Div 2)
|
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Ground Wire Size (AWG/MCM) | Nominal Diameter Over Armor | Nominal Diameter Overall Cable (in/mm) | Cable Weight (lbs/1000ft)/(kg/km) | Ampacity (30°C ambient) | Max. Pulling Tension (Pulling Eye) (lb/ kg) | Min. Bend Radius (Pull) (in/mm) |
2C610U140200709 | 2 | 14 | 14 | 0.51 / 12.95 | 0.622 / 15.8 | 172 / 256 | 25 | 66 / 30 | 11.2 / 284 |
2C610U140300709 | 3 | 14 | 14 | 0.541 / 13.73 | 0.653 / 16.58 | 192 / 285 | 25 | 99 / 45 | 11.7 / 298 |
2C610U140400709 | 4 | 14 | 14 | 0.574 / 14.58 | 0.686 / 17.42 | 217 / 323 | 20 | 132 / 60 | 12.3 / 314 |
2C610U140500709 | 5 | 14 | 14 | 0.603 / 15.32 | 0.715 / 18.16 | 242 / 361 | 20 | 165 / 75 | 12.9 / 327 |
2C610U140600709 | 6 | 14 | 14 | 0.643 / 16.33 | 0.755 / 19.18 | 271 / 404 | 20 | 197 / 90 | 13.6 / 345 |
2C610U140700709 | 7 | 14 | 14 | 0.683 / 17.35 | 0.795 / 20.19 | 301 / 447 | 17.5 | 230 / 104 | 14.3 / 363 |
2C610U140800709 | 8 | 14 | 14 | 0.724 / 18.39 | 0.836 / 21.24 | 330 / 492 | 17.5 | 263 / 119 | 15 / 382 |
2C610U141000709 | 10 | 14 | 14 | 0.776 / 19.71 | 0.888 / 22.56 | 375 / 558 | 12.5 | 329 / 149 | 16 / 406 |
2C610U141200709 | 12 | 14 | 14 | 0.796 / 20.22 | 0.908 / 23.06 | 412 / 613 | 12.5 | 395 / 179 | 16.3 / 415 |
2C610U141400709 | 14 | 14 | 14 | 0.831 / 21.09 | 0.942 / 23.94 | 457 / 681 | 12.5 | 461 / 209 | 17 / 431 |
2C610U141500709 | 15 | 14 | 14 | 0.849 / 21.57 | 0.961 / 24.41 | 479 / 713 | 12.5 | 494 / 224 | 17.3 / 439 |
2C610U142000709 | 20 | 14 | 14 | 0.949 / 24.1 | 1.061 / 26.95 | 590 / 879 | 12.5 | 658 / 298 | 19.1 / 485 |
2C610U142500709 | 25 | 14 | 14 | 1.006 / 25.55 | 1.118 / 28.4 | 696 / 1036 | 11.25 | 823 / 373 | 20.1 / 511 |
2C610U143000709 | 30 | 14 | 14 | 1.06 / 26.94 | 1.173 / 29.78 | 792 / 1178 | 11.25 | 987 / 448 | 21.1 / 536 |
2C610U144000709 | 40 | 14 | 14 | 1.179 / 29.94 | 1.291 / 32.79 | 997 / 1484 | 10 | 1316 / 597 | 23.2 / 590 |
2C610U145000709 | 50 | 14 | 14 | 1.304 / 33.12 | 1.416 / 35.96 | 1198 / 1783 | 8.75 | 1645 / 746 | 25.5 / 647 |
2C610U120200709 | 2 | 12 | 12 | 0.546 / 13.87 | 0.658 / 16.71 | 206 / 306 | 30 | 104 / 47 | 11.8 / 301 |
2C610U120300709 | 3 | 12 | 12 | 0.581 / 14.75 | 0.693 / 17.6 | 234 / 348 | 30 | 157 / 71 | 12.5 / 317 |
2C610U120400709 | 4 | 12 | 12 | 0.618 / 15.71 | 0.73 / 18.55 | 269 / 400 | 24 | 209 / 95 | 13.1 / 334 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16. Values are corrected according to Table 310.15(C)(1) for number of Conductors.
Part Number | Number of Conductors | Conductor Size (AWG/MCM) | Ground Wire Size (AWG/MCM) | Nominal Diameter Over Armor | Nominal Diameter Overall Cable (in/mm) | Cable Weight (lbs/1000ft)/(kg/km) | Ampacity (30°C ambient) | Max.PullingTension (PullingEye)(lb/kg) | Min. Bend Radius (Pull) (in/mm) |
2C610U120500709 | 5 | 12 | 12 | 0.652 / 16.55 | 0.764 / 19.4 | 304 / 453 | 24 | 261 / 118 | 13.7 / 349 |
2C610U120600709 | 6 | 12 | 12 | 0.697 / 17.7 | 0.809 / 20.55 | 344 / 511 | 24 | 313 / 142 | 14.6 / 370 |
2C610U120700709 | 7 | 12 | 12 | 0.742 / 18.85 | 0.854 / 21.7 | 382 / 569 | 21 | 365 / 166 | 15.4 / 391 |
2C610U120800709 | 8 | 12 | 12 | 0.789 / 20.04 | 0.901 / 22.89 | 423 / 630 | 21 | 418 / 189 | 16.2 / 412 |
2C610U121000709 | 10 | 12 | 12 | 0.848 / 21.54 | 0.96 / 24.38 | 486 / 723 | 15 | 522 / 237 | 17.3 / 439 |
2C610U121200709 | 12 | 12 | 12 | 0.871 / 22.12 | 0.983 / 24.96 | 541 / 805 | 15 | 626 / 284 | 17.7 / 449 |
2C610U121400709 | 14 | 12 | 12 | 0.91 / 23.11 | 1.022 / 25.96 | 602 / 896 | 15 | 731 / 331 | 18.4 / 467 |
2C610U121500709 | 15 | 12 | 12 | 0.931 / 23.65 | 1.043 / 26.49 | 633 / 942 | 15 | 783 / 355 | 18.8 / 477 |
2C610U122000709 | 20 | 12 | 12 | 1.008 / 25.61 | 1.12 / 28.46 | 784 / 1166 | 15 | 1044 / 474 | 20.2 / 512 |
2C610U122500709 | 25 | 12 | 12 | 1.114 / 28.3 | 1.226 / 31.14 | 944 / 1404 | 13.5 | 1305 / 592 | 22.1 / 561 |
2C610U123000709 | 30 | 12 | 12 | 1.176 / 29.87 | 1.288 / 32.71 | 1081 / 1608 | 13.5 | 1566 / 710 | 23.2 / 589 |
2C610U124000709 | 40 | 12 | 12 | 1.31 / 33.28 | 1.422 / 36.13 | 1375 / 2047 | 12 | 2088 / 947 | 25.6 / 650 |
2C610U125000709 | 50 | 12 | 12 | 1.452 / 36.89 | 1.564 / 39.73 | 1664 / 2476 | 10.5 | 2610 / 1184 | 28.2 / 715 |
2C610U100200709 | 2 | 10 | 10 | 0.596 / 15.14 | 0.708 / 17.98 | 258 / 383 | 40 | 166 / 75 | 12.7 / 324 |
2C610U100300709 | 3 | 10 | 10 | 0.637 / 16.17 | 0.748 / 19.01 | 304 / 453 | 40 | 249 / 113 | 13.5 / 342 |
2C610U100400709 | 4 | 10 | 10 | 0.68 / 17.28 | 0.792 / 20.13 | 349 / 520 | 32 | 332 / 151 | 14.3 / 362 |
2C610U100500709 | 5 | 10 | 10 | 0.719 / 18.27 | 0.831 / 21.11 | 398 / 593 | 32 | 415 / 188 | 15 / 380 |
2C610U100600709 | 6 | 10 | 10 | 0.772 / 19.61 | 0.884 / 22.45 | 454 / 675 | 32 | 498 / 226 | 15.9 / 404 |
2C610U100700709 | 7 | 10 | 10 | 0.825 / 20.95 | 0.937 / 23.79 | 509 / 757 | 28 | 581 / 264 | 16.9 / 428 |
2C610U100800709 | 8 | 10 | 10 | 0.879 / 22.33 | 0.991 / 25.18 | 567 / 843 | 28 | 664 / 301 | 17.8 / 453 |
2C610U101000709 | 10 | 10 | 10 | 0.948 / 24.08 | 1.06 / 26.92 | 655 / 975 | 20 | 830 / 376 | 19.1 / 485 |
2C610U101200709 | 12 | 10 | 10 | 0.974 / 24.75 | 1.086 / 27.59 | 738 / 1098 | 20 | 996 / 452 | 19.6 / 497 |
2C610U101400709 | 14 | 10 | 10 | 0.984 / 25 | 1.096 / 27.84 | 823 / 1225 | 20 | 1162 / 527 | 19.7 / 501 |
2C610U101500709 | 15 | 10 | 10 | 1.009 / 25.62 | 1.121 / 28.47 | 868 / 1291 | 20 | 1245 / 565 | 20.2 / 512 |
2C610U102000709 | 20 | 10 | 10 | 1.141 / 28.98 | 1.253 / 31.82 | 1094 / 1628 | 20 | 1660 / 753 | 22.6 / 573 |
2C610U102500709 | 25 | 10 | 10 | 1.264 / 32.11 | 1.376 / 34.95 | 1325 / 1972 | 18 | 2075 / 941 | 24.8 / 629 |
2C610U103000709 | 30 | 10 | 10 | 1.336 / 33.94 | 1.448 / 36.78 | 1532 / 2279 | 18 | 2490 / 1129 | 26.1 / 662 |
2C610U104000709 | 40 | 10 | 10 | 1.493 / 37.92 | 1.605 / 40.76 | 1964 / 2923 | 16 | 3320 / 1506 | 28.9 / 734 |
2C610U105000709 | 50 | 10 | 10 | 1.658 / 42.12 | 1.79 / 45.47 | 2424 / 3607 | 14 | 4150 / 1882 | 32.2 / 819 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16. Values are corrected according to Table 310.15(C)(1) for number of Conductors.
|
|
Related products
-
UL Metal Clad Armored AIA Power | Multi-Conductor (600/1000V)
Read moreUL Metal Clad Armored AIA Power | Multi-Conductor (600/1000V)
Metal-clad AIA power cables are suitable for use in ventilated, non-ventilated and ladder-type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40°C (40°F) environments. Applicable for use in utility, industrial and commercial applications.
SKU: 1753 Categories: UL Type MC Metal Clad Cable, UL Type TC Tray Cable, Building WireUL Metal Clad Armored AIA Power | Multi-Conductor (600/1000V)
Metal-clad AIA power cables are suitable for use in ventilated, non-ventilated and ladder-type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40°C (40°F) environments. Applicable for use in utility, industrial and commercial applications.
MORE DETAILS -
UL XHHW-2 | Single Conductor (600/1000V)
Read moreUL XHHW-2 | Single Conductor (600/1000V)
For use in open wiring and raceways (with the exception of cable troughs and ventilated flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum conductor temperature 90°C.
SKU: 1691 Categories: CSA Type TC Tray Cable, UL Type TC Tray Cable, Building WireUL XHHW-2 | Single Conductor (600/1000V)
For use in open wiring and raceways (with the exception of cable troughs and ventilated flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum conductor temperature 90°C.
MORE DETAILS -
UL EPR RHW-2 | Single Conductor (600V)
Read moreUL EPR RHW-2 | Single Conductor (600V)
For use in open wiring and raceways (with the exception of cable troughs and ventilated flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum conductor temperature 90°C.
SKU: 1667 Categories: CSA Type TC Tray Cable, UL Type TC Tray Cable, Building WireUL EPR RHW-2 | Single Conductor (600V)
For use in open wiring and raceways (with the exception of cable troughs and ventilated flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum conductor temperature 90°C.
MORE DETAILS