Home UL Type MC Metal Clad Cable UL Type MC Armored Power, Single Conductor, 600/1000 V

UL Type MC Armored Power, Single Conductor, 600/1000 V
Construction
Voltage
600V, 1000 V (optional)
Product Construction
-
- Insulation:
- FR XLPE (XHHW-2 rated) rated: 90°C wet / dry
- Armor:
- Aluminum Interlocked Armor (AIA) (standard)
-
- Jacket:
- FR PVC inner / outer black jacket rated: 90°C to -40°C
- Thermoset CPE optional)
- Thermoplastic CPE (optional)
- Thermoplastic LSZH (optional)
- Jacket:
- Available in:
- Custom insulation / jacket colours
- Composite constructions (CT use)
Colour Coding
- Black conductors (standard)
- Method 4 (optional)
Certifications
Certifications/Compliances
- UL 1569, Metal Clad Cables (MC)
- UL 44, Thermoset Insulated Wires and Cables
- UL 1685 / FT4, Vertical Tray Flame Test rated
- IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- Strand Bare (ASTM B8) Annealed Copper Conductor
- FR XLPE (XHHW-2 Rated) Insulated Conductor
- UV sunlight resistant SUN RES (all colours) (for 3. Serve / Wound Grounds)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 20, 21 (Div 1)
- Class II Zone 22 (Div 2)
Properties
- Stranded Bare Copper Conductor (Tin-coated Available)
- FR XLPE (XHHW-2 Rated) Insulated Conductor
- Serve/Wound Grounds
- Polyester Separator Tape
- FR PVC Inner Protective Jacket
- Aluminum Interlocked Armor (AIA)
- FR PVC Outer Protective Jacket
| Part Number | Number of Pairs | Conductor Size | Ground Wire Size | OD Over Inner Jacket | Nominal Diameters | Cable Weight | Ampacity | Max. Pulling Tension (Pulling Eye) | Min. Bend Radius(Pull)) | |
| Over Armour | Overall Cable | |||||||||
| (AWG/kcmil) | (AWG/kcmil) | (in/ mm) | (in/mm) | (in/mm) | (lbs/1000ft)/ (kg/km) | (30°C ambient) | (lb/kg) | (in/mm) | ||
| 2C610U080100300 | 1 | 8 | 18 | 0.407 / 10.3 | 0.647 / 16.4 | 0.759 / 19.3 | 307 / 457 | 55 | 132 / 60 | 13.7 / 347 |
| 2C610U060100300 | 1 | 6 | 16 | 0.466 / 11.8 | 0.706 / 17.9 | 0.818 / 20.8 | 394 / 587 | 75 | 210 / 95 | 14.7 / 374 |
| 2C610U040100300 | 1 | 4 | 16 | 0.513 / 13.0 | 0.753 / 19.1 | 0.865 / 22 | 462 / 687 | 95 | 334 / 151 | 15.6 / 395 |
| 2C610U030100300 | 1 | 3 | 16 | 0.560 / 14.2 | 0.800 / 20.3 | 0.912 / 23.2 | 522 / 777 | 115 | 421 / 191 | 16.4 / 417 |
| 2C610U020100300 | 1 | 2 | 16 | 0.591 / 15.0 | 0.831 / 21.1 | 0.943 / 24.0 | 578 / 860 | 130 | 531 / 241 | 17 / 431 |
| 2C610U010140300 | 1 | 1 | 14 | 0.676 / 17.2 | 0.916 / 23.3 | 1.028 / 26.1 | 725 / 1079 | 145 | 670 / 304 | 18.5 / 470 |
| 2C610U1/0140300 | 1 | 1/0 | 14 | 0.716 / 18.2 | 0.956 / 24.3 | 1.068 / 27.1 | 811 / 1207 | 170 | 845 / 383 | 19.2 / 488 |
| 2C610U2/0140300 | 1 | 2/0 | 14 | 0.759 / 19.3 | 0.979 / 24.9 | 1.091 / 27.7 | 911 / 1356 | 195 | 1065 / 483 | 19.6 / 499 |
| 2C610U3/0140300 | 1 | 3/0 | 14 | 0.810 / 20.6 | 1.014 / 25.8 | 1.126 / 28.6 | 1066 / 1587 | 225 | 1336 / 606 | 20.3 / 515 |
| 2C610U4/0140300 | 1 | 4/0 | 14 | 0.866 / 22.0 | 1.070 / 27.2 | 1.182 / 30.0 | 1282 / 1908 | 260 | 1693 / 768 | 21.3 / 540 |
| 2C610U250160300 | 1 | 250 | 14 | 0.932 / 23.7 | 1.136 / 28.9 | 1.248 / 31.7 | 1427 / 2124 | 290 | 2000 / 907 | 22.5 / 571 |
| 2C610U300160300 | 1 | 300 | 14 | 0.985 / 25.0 | 1.189 / 30.2 | 1.301 / 33.1 | 1660 / 2471 | 320 | 2400 / 1089 | 23.4 / 595 |
| 2C610U350160300 | 1 | 350 | 14 | 1.035 / 26.3 | 1.239 / 31.5 | 1.351 / 34.3 | 1839 / 2737 | 350 | 2800 / 1270 | 24.3 / 618 |
| 2C610U500160300 | 1 | 500 | 14 | 1.163 / 29.5 | 1.367 / 34.7 | 1.479 / 37.6 | 2433 / 3620 | 430 | 4000 / 1814 | 26.6 / 676 |
| 2C610U750160300 | 1 | 750 | 14 | 1.372 / 34.9 | 1.576 / 40.0 | 1.708 / 43.4 | 3461 / 5151 | 535 | 6000 / 2722 | 30.7 / 781 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16.
Markets / Applications
|
|
Voltage
600V, 1000 V (optional)
Product Construction
-
- Insulation:
- FR XLPE (XHHW-2 rated) rated: 90°C wet / dry
- Armor:
- Aluminum Interlocked Armor (AIA) (standard)
-
- Jacket:
- FR PVC inner / outer black jacket rated: 90°C to -40°C
- Thermoset CPE optional)
- Thermoplastic CPE (optional)
- Thermoplastic LSZH (optional)
- Jacket:
- Available in:
- Custom insulation / jacket colours
- Composite constructions (CT use)
Colour Coding
- Black conductors (standard)
- Method 4 (optional)
Certifications/Compliances
- UL 1569, Metal Clad Cables (MC)
- UL 44, Thermoset Insulated Wires and Cables
- UL 1685 / FT4, Vertical Tray Flame Test rated
- IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
- ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
- XLPE (XHHW-2 rated), 90°C wet / dry
- Strand Bare (ASTM B8) Annealed Copper Conductor
- FR XLPE (XHHW-2 Rated) Insulated Conductor
- UV sunlight resistant SUN RES (all colours) (for 3. Serve / Wound Grounds)
- Direct burial rated
- -40°C cold bend rated
- Rated for use in hazardous locations:
- Class I Zone 2 (Div 2)
- Class II Zone 20, 21 (Div 1)
- Class II Zone 22 (Div 2)
- Stranded Bare Copper Conductor (Tin-coated Available)
- FR XLPE (XHHW-2 Rated) Insulated Conductor
- Serve/Wound Grounds
- Polyester Separator Tape
- FR PVC Inner Protective Jacket
- Aluminum Interlocked Armor (AIA)
- FR PVC Outer Protective Jacket
| Part Number | Number of Pairs | Conductor Size | Ground Wire Size | OD Over Inner Jacket | Nominal Diameters | Cable Weight | Ampacity | Max. Pulling Tension (Pulling Eye) | Min. Bend Radius(Pull)) | |
| Over Armour | Overall Cable | |||||||||
| (AWG/kcmil) | (AWG/kcmil) | (in/ mm) | (in/mm) | (in/mm) | (lbs/1000ft)/ (kg/km) | (30°C ambient) | (lb/kg) | (in/mm) | ||
| 2C610U080100300 | 1 | 8 | 18 | 0.407 / 10.3 | 0.647 / 16.4 | 0.759 / 19.3 | 307 / 457 | 55 | 132 / 60 | 13.7 / 347 |
| 2C610U060100300 | 1 | 6 | 16 | 0.466 / 11.8 | 0.706 / 17.9 | 0.818 / 20.8 | 394 / 587 | 75 | 210 / 95 | 14.7 / 374 |
| 2C610U040100300 | 1 | 4 | 16 | 0.513 / 13.0 | 0.753 / 19.1 | 0.865 / 22 | 462 / 687 | 95 | 334 / 151 | 15.6 / 395 |
| 2C610U030100300 | 1 | 3 | 16 | 0.560 / 14.2 | 0.800 / 20.3 | 0.912 / 23.2 | 522 / 777 | 115 | 421 / 191 | 16.4 / 417 |
| 2C610U020100300 | 1 | 2 | 16 | 0.591 / 15.0 | 0.831 / 21.1 | 0.943 / 24.0 | 578 / 860 | 130 | 531 / 241 | 17 / 431 |
| 2C610U010140300 | 1 | 1 | 14 | 0.676 / 17.2 | 0.916 / 23.3 | 1.028 / 26.1 | 725 / 1079 | 145 | 670 / 304 | 18.5 / 470 |
| 2C610U1/0140300 | 1 | 1/0 | 14 | 0.716 / 18.2 | 0.956 / 24.3 | 1.068 / 27.1 | 811 / 1207 | 170 | 845 / 383 | 19.2 / 488 |
| 2C610U2/0140300 | 1 | 2/0 | 14 | 0.759 / 19.3 | 0.979 / 24.9 | 1.091 / 27.7 | 911 / 1356 | 195 | 1065 / 483 | 19.6 / 499 |
| 2C610U3/0140300 | 1 | 3/0 | 14 | 0.810 / 20.6 | 1.014 / 25.8 | 1.126 / 28.6 | 1066 / 1587 | 225 | 1336 / 606 | 20.3 / 515 |
| 2C610U4/0140300 | 1 | 4/0 | 14 | 0.866 / 22.0 | 1.070 / 27.2 | 1.182 / 30.0 | 1282 / 1908 | 260 | 1693 / 768 | 21.3 / 540 |
| 2C610U250160300 | 1 | 250 | 14 | 0.932 / 23.7 | 1.136 / 28.9 | 1.248 / 31.7 | 1427 / 2124 | 290 | 2000 / 907 | 22.5 / 571 |
| 2C610U300160300 | 1 | 300 | 14 | 0.985 / 25.0 | 1.189 / 30.2 | 1.301 / 33.1 | 1660 / 2471 | 320 | 2400 / 1089 | 23.4 / 595 |
| 2C610U350160300 | 1 | 350 | 14 | 1.035 / 26.3 | 1.239 / 31.5 | 1.351 / 34.3 | 1839 / 2737 | 350 | 2800 / 1270 | 24.3 / 618 |
| 2C610U500160300 | 1 | 500 | 14 | 1.163 / 29.5 | 1.367 / 34.7 | 1.479 / 37.6 | 2433 / 3620 | 430 | 4000 / 1814 | 26.6 / 676 |
| 2C610U750160300 | 1 | 750 | 14 | 1.372 / 34.9 | 1.576 / 40.0 | 1.708 / 43.4 | 3461 / 5151 | 535 | 6000 / 2722 | 30.7 / 781 |
*Ampacity value based on National Electrical Code, Version 2020, Table 310.16.
|
|
Related products
-

CSA LSZH TYPE ACIC Armoured Control, Multi-Conductor, 1000 V
View Product: CSA LSZH TYPE ACIC Armoured Control, Multi-Conductor, 1000 VCSA LSZH TYPE ACIC Armoured Control, Multi-Conductor, 1000 V
LSZH AIA Control cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40°C (-40°F) environments. Applicable for use in Utilities, Industrial and Commercial applications.
SKU: 1535 Categories: CSA Type ACIC Armoured Control & Instrumentation, CSA Type Teck 90 Armoured Cable, Building WireCSA LSZH TYPE ACIC Armoured Control, Multi-Conductor, 1000 V
LSZH AIA Control cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40°C (-40°F) environments. Applicable for use in Utilities, Industrial and Commercial applications.
MORE DETAILS -

CSA Type ACIC Armoured Thermocouple Extension, 300 V
View Product: CSA Type ACIC Armoured Thermocouple Extension, 300 VCSA Type ACIC Armoured Thermocouple Extension, 300 V
Shawflex Thermocouple Extension cables offer advantages in cost and mechanical properties when used for connections between thermocouples and instruments.
SKU: 1533 Categories: CSA Type ACIC Armoured Control & Instrumentation, Thermocouple Extension Cable, Building WireCSA Type ACIC Armoured Thermocouple Extension, 300 V
Shawflex Thermocouple Extension cables offer advantages in cost and mechanical properties when used for connections between thermocouples and instruments.
MORE DETAILS -

UL Type MC Armored VFD, Multi-Conductor, 600/1000 V
View Product: UL Type MC Armored VFD, Multi-Conductor, 600/1000 VUL Type MC Armored VFD, Multi-Conductor, 600/1000 V
Shawflex VFD cables are the preferred power cables for AC Drives. These cables are primarily used between Pulse Width Modulation (PWM) inverters and AC motors. Tray cables are suitable for use in raceways, including ventilated, non-ventilated, indoor / outdoor and ladder-type cable trays in wet / dry locations and are applicable in Industrial and Processing facilities.
SKU: 1676 Categories: UL Type MC Metal Clad Cable, UL Type TC Tray Cable, Variable Frequency Drive (VFD), Thermocouple Extension Cable, Building WireUL Type MC Armored VFD, Multi-Conductor, 600/1000 V
Shawflex VFD cables are the preferred power cables for AC Drives. These cables are primarily used between Pulse Width Modulation (PWM) inverters and AC motors. Tray cables are suitable for use in raceways, including ventilated, non-ventilated, indoor / outdoor and ladder-type cable trays in wet / dry locations and are applicable in Industrial and Processing facilities.
MORE DETAILS