UL Type MC Armored Power, Single Conductor, 2000 V

Metal Clad AIA Power cables are suitable for use in ventilated, non-ventilated and ladder type cable trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry locations in -40°C (-40°F) environments. Applicable for use in Utilities, Industrial and Commercial applications.
UL

Construction

Voltage

2000V

Product Construction

  • Insulation:
    • -FR XLPE (XHHW-2 rated)
    • rated: 90°C wet / dry
  • Jacket:
    • FR PVC inner / outer black jacket
    • rated: 90°C to -40°C
    • Thermoset CPE optional)
    • Thermoplastic CPE (optional)
    • Thermoplastic LSZH (optional)
  • Available in:
    • Custom insulation / jacket colours
    • Composite constructions (CT use)
  • Armor:
    • Aluminum Interlocked Armor (AIA) (standard)

Certifications

Certifications/Compliances

  • UL 1569, Metal Clad Cables (MC)
  • UL 44, Thermoset Insulated Wires and Cables
  • UL 1685 / FT4, Vertical Tray Flame Test rated
  • IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
  • ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
  • XLPE (XHHW-2 rated), 90°C wet / dry
  • Strand Bare (ASTM B8) Annealed Copper Conductor
  • FR XLPE (XHHW-2 Rated) Insulated Conductor
  • UV sunlight resistant UN RES (all colours)
  • Direct burial rated
  • -40°C cold bend rated
  • Rated for use in hazardous locations:
    • Class I Zone 2 (Div 2)
    • Class II Zone 20, 21 (Div 1)
    • Class II Zone 22 (Div 2)

Colour Coding

  • Black conductors (standard)
  • Method 4 (optional)

Properties

  1. Stranded Bare Copper Conductor (Tin-coated Available)
  2. FR XLPE (RHW-2 Rated) Insulated Conductor
  3. Serve/Wound Grounds
  4. Polyester Separator Tape
  5. FR PVC Inner Protective Jacket
  6. Aluminum Interlocked Armor (AIA)
  7. FR PVC Outer Protective Jacket

Part Number Number of Pairs Conductor Size Ground Wire Size OD Over Inner Jacket Nominal Diameters Cable Weight Ampacity Max. Pulling Tension (Pulling Eye) Min. Bend Radius(Pull)
Over Armour Overall Cable
(AWG/kcmil) (AWG/kcmil) (in/ mm) (in/mm) (in/mm) (lbs/1000ft)/ (kg/km) (30°C ambient) (lb/kg) (in/mm)
2K610U080100300 1 8 18 0.457 / 11.6 0.697 / 17.7 0.809 / 20.6 334 / 498 55 132 / 60 14.6 / 370
2K610U060100300 1 6 16 0.516 / 13.1 0.756 / 19.2 0.868 / 22.1 423 / 630 75 210 / 95 15.6 / 397
2K610U040100300 1 4 16 0.583 / 14.8 0.823 / 20.9 0.935 / 23.8 509 / 757 95 334 / 151 16.8 / 427
2K610U030100300 1 3 16 0.610 / 15.5 0.850 / 21.6 0.962 / 24.4 556 / 827 115 421 / 191 17.3 / 440
2K610U020100300 1 2 16 0.641 / 16.3 0.881 / 22.4 0.993 / 25.2 613 / 912 130 531 / 241 17.9 / 454
2K610U010140300 1 1 14 0.746 / 19.0 0.986 / 25.0 1.098 / 27.9 778 / 1157 145 670 / 304 19.8 / 502
2K610U1/0140300 1 1/0 14 0.786 / 20.0 0.990 / 25.2 1.102 / 28.0 859 / 1278 170 845 / 383 19.8 / 504
2K610U2/0140300 1 2/0 14 0.829 / 21.1 1.033 / 26.2 1.145 / 29.1 966 / 1438 195 1065 / 483 20.6 / 523
2K610U3/0140300 1 3/0 14 0.880 / 22.4 1.084 / 27.5 1.196 / 30.4 1127 / 1678 225 1336 / 606 21.5 / 547
2K610U4/0140300 1 4/0 14 0.936 / 23.8 1.140 / 29.0 1.252 / 31.8 1346 / 2004 260 1693 / 768 22.5 / 572
2K610U250160300 1 250 14 1.012 / 25.7 1.216 / 30.9 1.328 / 33.7 1506 / 2241 290 2000 / 907 23.9 / 607
2K610U300160300 1 300 14 1.065 / 27.1 1.269 / 32.2 1.381 / 35.1 1744 / 2596 320 2400 / 1089 24.9 / 631
2K610U350160300 1 350 14 1.115 / 28.3 1.319 / 33.5 1.431 / 36.4 1926 / 2867 350 2800 / 1270 25.8 / 654
2K610U500160300 1 500 14 1.243 / 31.6 1.447 / 36.8 1.559 / 39.6 2530 / 3765 430 4000 / 1814 28.1 / 713
2K610U750160300 1 750 14 1.452 / 36.9 1.656 / 42.1 1.788 / 45.4 3578 / 5324 535 6000 / 2722 32.2 / 817

*Ampacity value based on National Electrical Code, Version 2020, Table 310.16

Markets / Applications

  • Generation – Renewables – Wind
  • Transit
  • Water/Waste Water Treatment
  • Generation – Traditional Power
  • Generation
  • Communication Power & Control
  • Generation – Nuclear
  • Power Distribution
  • Industrial Construction/Automation
  • Civil Construction Projects
  • Power Distribution – LV
  • Industrial
  • Generation – Renewables
  • Petrochem/Pulp & Paper
  • Utility
  • Commercial Construction Projects
  • OIl & Gas
  • Generation – Renewables – Geo Thermal
  • Mining

Voltage

2000V

Product Construction

  • Insulation:
    • -FR XLPE (XHHW-2 rated)
    • rated: 90°C wet / dry
  • Jacket:
    • FR PVC inner / outer black jacket
    • rated: 90°C to -40°C
    • Thermoset CPE optional)
    • Thermoplastic CPE (optional)
    • Thermoplastic LSZH (optional)
  • Available in:
    • Custom insulation / jacket colours
    • Composite constructions (CT use)
  • Armor:
    • Aluminum Interlocked Armor (AIA) (standard)

Certifications/Compliances

  • UL 1569, Metal Clad Cables (MC)
  • UL 44, Thermoset Insulated Wires and Cables
  • UL 1685 / FT4, Vertical Tray Flame Test rated
  • IEEE 1202 / 383 (70,000 BTU / hr), Vertical Flame Test rated
  • ICEA T-30-520 (70,000 BTU / hr), Vertical Flame Test rated
  • XLPE (XHHW-2 rated), 90°C wet / dry
  • Strand Bare (ASTM B8) Annealed Copper Conductor
  • FR XLPE (XHHW-2 Rated) Insulated Conductor
  • UV sunlight resistant UN RES (all colours)
  • Direct burial rated
  • -40°C cold bend rated
  • Rated for use in hazardous locations:
    • Class I Zone 2 (Div 2)
    • Class II Zone 20, 21 (Div 1)
    • Class II Zone 22 (Div 2)

Colour Coding

  • Black conductors (standard)
  • Method 4 (optional)
  1. Stranded Bare Copper Conductor (Tin-coated Available)
  2. FR XLPE (RHW-2 Rated) Insulated Conductor
  3. Serve/Wound Grounds
  4. Polyester Separator Tape
  5. FR PVC Inner Protective Jacket
  6. Aluminum Interlocked Armor (AIA)
  7. FR PVC Outer Protective Jacket

Part Number Number of Pairs Conductor Size Ground Wire Size OD Over Inner Jacket Nominal Diameters Cable Weight Ampacity Max. Pulling Tension (Pulling Eye) Min. Bend Radius(Pull)
Over Armour Overall Cable
(AWG/kcmil) (AWG/kcmil) (in/ mm) (in/mm) (in/mm) (lbs/1000ft)/ (kg/km) (30°C ambient) (lb/kg) (in/mm)
2K610U080100300 1 8 18 0.457 / 11.6 0.697 / 17.7 0.809 / 20.6 334 / 498 55 132 / 60 14.6 / 370
2K610U060100300 1 6 16 0.516 / 13.1 0.756 / 19.2 0.868 / 22.1 423 / 630 75 210 / 95 15.6 / 397
2K610U040100300 1 4 16 0.583 / 14.8 0.823 / 20.9 0.935 / 23.8 509 / 757 95 334 / 151 16.8 / 427
2K610U030100300 1 3 16 0.610 / 15.5 0.850 / 21.6 0.962 / 24.4 556 / 827 115 421 / 191 17.3 / 440
2K610U020100300 1 2 16 0.641 / 16.3 0.881 / 22.4 0.993 / 25.2 613 / 912 130 531 / 241 17.9 / 454
2K610U010140300 1 1 14 0.746 / 19.0 0.986 / 25.0 1.098 / 27.9 778 / 1157 145 670 / 304 19.8 / 502
2K610U1/0140300 1 1/0 14 0.786 / 20.0 0.990 / 25.2 1.102 / 28.0 859 / 1278 170 845 / 383 19.8 / 504
2K610U2/0140300 1 2/0 14 0.829 / 21.1 1.033 / 26.2 1.145 / 29.1 966 / 1438 195 1065 / 483 20.6 / 523
2K610U3/0140300 1 3/0 14 0.880 / 22.4 1.084 / 27.5 1.196 / 30.4 1127 / 1678 225 1336 / 606 21.5 / 547
2K610U4/0140300 1 4/0 14 0.936 / 23.8 1.140 / 29.0 1.252 / 31.8 1346 / 2004 260 1693 / 768 22.5 / 572
2K610U250160300 1 250 14 1.012 / 25.7 1.216 / 30.9 1.328 / 33.7 1506 / 2241 290 2000 / 907 23.9 / 607
2K610U300160300 1 300 14 1.065 / 27.1 1.269 / 32.2 1.381 / 35.1 1744 / 2596 320 2400 / 1089 24.9 / 631
2K610U350160300 1 350 14 1.115 / 28.3 1.319 / 33.5 1.431 / 36.4 1926 / 2867 350 2800 / 1270 25.8 / 654
2K610U500160300 1 500 14 1.243 / 31.6 1.447 / 36.8 1.559 / 39.6 2530 / 3765 430 4000 / 1814 28.1 / 713
2K610U750160300 1 750 14 1.452 / 36.9 1.656 / 42.1 1.788 / 45.4 3578 / 5324 535 6000 / 2722 32.2 / 817

*Ampacity value based on National Electrical Code, Version 2020, Table 310.16

  • Generation – Renewables – Wind
  • Transit
  • Water/Waste Water Treatment
  • Generation – Traditional Power
  • Generation
  • Communication Power & Control
  • Generation – Nuclear
  • Power Distribution
  • Industrial Construction/Automation
  • Civil Construction Projects
  • Power Distribution – LV
  • Industrial
  • Generation – Renewables
  • Petrochem/Pulp & Paper
  • Utility
  • Commercial Construction Projects
  • OIl & Gas
  • Generation – Renewables – Geo Thermal
  • Mining