CSA TYPE TECK 90 Armoured Vertical Mineshaft, 1000 V

Vertical Mineshaft TECK 90 cables are designed for vertical applications to prevent cable core slippage and are suitable for use in mineshaft and for environments that require self-supporting lengths. Typically used in Mining, Utilities, Industrial and Commercial applications.
CSA

Construction

Voltage

1000 V
Optional: 600 V

Product Construction

Insulation:
XLPE (RW90 rated) rated: 90°C wet/dry

Armour:
Steel Interlocked Armour (SIA) (standard)
Aluminum Interlocked Armour (AIA) (optional)

Jacket:
FR LAG PVC (AG14 rated) inner ribbed black jacket rated: 90°C to -40°C
FR LAG PVC (AG14 rated) outer black jacket rated: 90°C to -40°C

Available in:
Variable Frequency Drive (VFD)
Custom insulation/jacket colours
Composite constructions
Aluminum conductors
Single conductor

Certifications

Certifications/Compliances

  • CSA C22.2 No. 131, Type TECK 90 cable
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 2556/UL 2556 FT4, Vertical Tray Flame Test rated
  • IEEE 383/1202 (70,000 BTU/hr), Vertical Flame Test rated
  • XLPE (RW90 rated), 90°C wet/dry
  • UV sunlight resistant SUN RES (all colours)
  • Direct burial rated
  • -40°C cold bend/impact rated
  • HL rated for use in hazardous locations:
    • Zone 0 (Class 1, Division 1) (Intrinsically Safe circuits only)
    • Zone 1 (Class I, Division 1), Zone 2 (Class I, Division 2)
    • Zone 20 & 21 (Class II & III, Division 1), Zone 22 (Class II & III, Division 2)

Colour Coding

  • 2C Black & white
  • 3C Black, red & blue
  • 4C Black, red, blue & white
  • 5C and greater – Black, number-coded with white ink

Properties

  1. Stranded Bare (ASTM B8) Annealed Copper Conductors
  2. Bonding Conductor
  3. XLPE (RW90 Rated) Insulated Conductors
  4. Cloth-backed Rubberized Separator Tape
  5. FR LAG PVC Inner Ribbed Protective Jacket
  6. Steel Interlocked Armour (SIA)
  7. FR LAG PVC Outer Protective Jacket

TECK 90 Armoured Vertical Mineshaft Cable 1000 V

Part Number Number of Conductors Conductor Size Bonding Conductor Size Nominal Diameter Cable Weight Ampacity* Max. Pulling Tension (Pulling Eye) Min. Bend Radius (Pull) Self- support Length
AWG or kcmil AWG Over Inner Jacket
in. | mm
Over Armour
in. | mm
Overall Cable
in. | mm
lb/1000ft |
kg/km
30°C ambient lb | kg in. | mm ft | m
80110M1/034070V 3 1/0 6 1.328 | 33.7 1.673 | 42.5 1.781 | 45.2 2775 | 4130 170 2534 | 1150 32.0 | 814 663 | 202
80110M2/034070V 3 2/0 6 1.420 | 36.1 1.830 | 46.5 1.938 | 49.2 3394 | 5051 195 3194 | 1449 35.0 | 886 684 | 208
80110M3/034070V 3 3/0 4 1.530 | 38.9 1.940 | 49.3 2.048 | 52.0 3929 | 5848 225 4027 | 1827 37.0 | 936 745 | 227
80110M4/034070V 3 4/0 4 1.650 | 41.9 2.060 | 52.3 2.168 | 55.1 4536 | 6751 260 5078 | 2304 39.0 | 991 813 | 248
80110M25036070V 3 250 4 1.852 | 47.1 2.262 | 57.5 2.394 | 60.8 5311 | 7904 290 6000 | 2722 43.0 | 1095 821 | 250
80110M35036070V 3 350 3 2.074 | 52.7 2.484 | 63.1 2.616 | 66.4 6722 | 10003 350 8400 | 3810 47.0 | 1196 908 | 277
80110M50036070V 3 500 3 2.349 | 59.7 2.759 | 70.1 2.891 | 73.4 8617 | 12824 430 12000 | 5443 52.0 | 1322 1012 | 308
80110M75036070V 3 750 2 2.734 | 69.4 3.206 | 81.4 3.352 | 85.2 11951 | 17785 535 18000 | 8165 60.0 | 1533 1094 | 333

*Ampacity value based on Canadian Electrical Code, Part 1 (2021 25th Edition), Table 2. Values are corrected for number of insulated conductors as applicable according to Table 5C.

Markets / Applications

  • Industrial
  • Commercial Construction Projects
  • Mining

Voltage

1000 V
Optional: 600 V

Product Construction

Insulation:
XLPE (RW90 rated) rated: 90°C wet/dry

Armour:
Steel Interlocked Armour (SIA) (standard)
Aluminum Interlocked Armour (AIA) (optional)

Jacket:
FR LAG PVC (AG14 rated) inner ribbed black jacket rated: 90°C to -40°C
FR LAG PVC (AG14 rated) outer black jacket rated: 90°C to -40°C

Available in:
Variable Frequency Drive (VFD)
Custom insulation/jacket colours
Composite constructions
Aluminum conductors
Single conductor

Certifications/Compliances

  • CSA C22.2 No. 131, Type TECK 90 cable
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 2556/UL 2556 FT4, Vertical Tray Flame Test rated
  • IEEE 383/1202 (70,000 BTU/hr), Vertical Flame Test rated
  • XLPE (RW90 rated), 90°C wet/dry
  • UV sunlight resistant SUN RES (all colours)
  • Direct burial rated
  • -40°C cold bend/impact rated
  • HL rated for use in hazardous locations:
    • Zone 0 (Class 1, Division 1) (Intrinsically Safe circuits only)
    • Zone 1 (Class I, Division 1), Zone 2 (Class I, Division 2)
    • Zone 20 & 21 (Class II & III, Division 1), Zone 22 (Class II & III, Division 2)

Colour Coding

  • 2C Black & white
  • 3C Black, red & blue
  • 4C Black, red, blue & white
  • 5C and greater – Black, number-coded with white ink
  1. Stranded Bare (ASTM B8) Annealed Copper Conductors
  2. Bonding Conductor
  3. XLPE (RW90 Rated) Insulated Conductors
  4. Cloth-backed Rubberized Separator Tape
  5. FR LAG PVC Inner Ribbed Protective Jacket
  6. Steel Interlocked Armour (SIA)
  7. FR LAG PVC Outer Protective Jacket

TECK 90 Armoured Vertical Mineshaft Cable 1000 V

Part Number Number of Conductors Conductor Size Bonding Conductor Size Nominal Diameter Cable Weight Ampacity* Max. Pulling Tension (Pulling Eye) Min. Bend Radius (Pull) Self- support Length
AWG or kcmil AWG Over Inner Jacket
in. | mm
Over Armour
in. | mm
Overall Cable
in. | mm
lb/1000ft |
kg/km
30°C ambient lb | kg in. | mm ft | m
80110M1/034070V 3 1/0 6 1.328 | 33.7 1.673 | 42.5 1.781 | 45.2 2775 | 4130 170 2534 | 1150 32.0 | 814 663 | 202
80110M2/034070V 3 2/0 6 1.420 | 36.1 1.830 | 46.5 1.938 | 49.2 3394 | 5051 195 3194 | 1449 35.0 | 886 684 | 208
80110M3/034070V 3 3/0 4 1.530 | 38.9 1.940 | 49.3 2.048 | 52.0 3929 | 5848 225 4027 | 1827 37.0 | 936 745 | 227
80110M4/034070V 3 4/0 4 1.650 | 41.9 2.060 | 52.3 2.168 | 55.1 4536 | 6751 260 5078 | 2304 39.0 | 991 813 | 248
80110M25036070V 3 250 4 1.852 | 47.1 2.262 | 57.5 2.394 | 60.8 5311 | 7904 290 6000 | 2722 43.0 | 1095 821 | 250
80110M35036070V 3 350 3 2.074 | 52.7 2.484 | 63.1 2.616 | 66.4 6722 | 10003 350 8400 | 3810 47.0 | 1196 908 | 277
80110M50036070V 3 500 3 2.349 | 59.7 2.759 | 70.1 2.891 | 73.4 8617 | 12824 430 12000 | 5443 52.0 | 1322 1012 | 308
80110M75036070V 3 750 2 2.734 | 69.4 3.206 | 81.4 3.352 | 85.2 11951 | 17785 535 18000 | 8165 60.0 | 1533 1094 | 333

*Ampacity value based on Canadian Electrical Code, Part 1 (2021 25th Edition), Table 2. Values are corrected for number of insulated conductors as applicable according to Table 5C.

  • Industrial
  • Commercial Construction Projects
  • Mining