Home RTD Cable Assembly Failure & Replacement Project
RTD Cable Assembly Failure & Replacement Project
RTD cable assembly failure & replacement at a major Canadian nuclear power plant.
A major nuclear power plant operator in Canada was experiencing frequent failure with their RTD assemblies, that put the operation of the plant at risk. Like many CANDU plants around the world, Resistance Temperature Detectors (RTDs) connector assemblies are used in critical temperature measurement loops.
Results
The new design was successfully EQ qualified for 30 years. The RTD Cable Assembly has not failed in service and is far exceeding administrative limits and past operational experience. The success of the new design led to all CANDU NPP operators to switch to the new design. Kanata regularly supplies RTD Cable Assemblies to CANDU Operators around the world.