ARMORED INSTRUMENTATION | PAIRS & TRIADS (300V) 
PAGE 1 OF 2



Armored Instrumentation cables can be used to minimize noise and signal interference by 

preventing crosstalk between pairs and triads. This cable can also be used to convert analogue 
or digital signals. Tray Instrumentation cables can be installed in raceways, direct burial 
applications and in outdoor exposed industrial applications.



Voltage
Certifications/Compliances
46
300V
• UL 13, Power Limited Tray Cable (PLTC)
• UL 2250, Instrumentation Tray Cable (ITC) 1 2
3 5 7 8 9
Product Construction
• UL 83, Thermoplastic Insulated WIres and
• Insulation: Cables

- FR PVC
• UL 1685 / FT4, Vertical Tray Flame Test rated 
• IEEE 1202/383 (70,000 BTU/hr), Vertical
rated: 60°C wet/105°C dry 1. Stranded Bare Copper Conductors (Tinned Available) 
-
Flame Test rated
XLPE rated optional)
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame
VW-1 rated (optional)
2. FR PVC Insulated Conductors
-
3. Individual Shield & Overall Shielded Pairs/Triads 
Test rated
4. Polypropylene Fillers
• Shielding (foil-free edge):
• UV sunlight resistant “SUN RES” (all colours) - ISOS (standard)
• -40°C cold bend rated
5. Polyester Separator Tape
- OS (optional) 
6. Overall Aluminum/Mylar Shield with Tinned Copper
• Armour:
• Rated for use in hazardous locations:
Drain Wire
- Class I Zone 2 (Div 2)
7. FR PVC Inner Protective Jacket
- Aluminum Interlocked Armor (standard) 
- Class II Zone 22 (Div 2)
- Steel Interlocked Armor (optional) 
8. Aluminum Interlocked Armor (AIA) - Served Wire Armor (SWA) (optional) 
9. FR PVC Outer Protective Jacket
-
Zetabon (optional)
Colour Coding
• Jacket:
• Pairs - Black, & white, with black printing on -
FR PVC outer black jacket (standard) 
white (standard)
rated: 90°C to -40°C

• Triads - Black, white & red, with black printing - Thermoset CPE (optional) 
on white (standard)
- Thermoplastic CPE (optional) 
-
Thermoplastic LSZH (optional)
• Available in:

- Custom insulation/jacket colors 
- Composite constructions

PAIRS


Normal Diameters
OD Over Cable Weight Min. Bend Radius 
Part Number
Number of Conductor Size Inner Jacket (lbs/1000ft)/ Max. Pulling Tension (Pull) 
Components
(AWG/MCM)
(in/mm)
Overall Cable (kg/km)
(Pulling Eye) (lb/kg)
(in/mm)
Over Armour 
(in/mm)
(in/mm)

23621U160100700
1
16
0.267 / 6.78
0.507 / 12.88
0.619 / 15.72
159 / 237
41 / 19
11.1 / 283

23622U160200700
14 / 356
2
16
0.426 / 10.81
0.666 / 16.91
0.778 / 19.75
260 / 387
82 / 37
15.2 / 386
23622U160400700
4
16
0.492 / 12.5
0.732 / 18.59
0.844 / 21.44
324 / 482
165 / 75

23622U160600700 16.9 / 429
6
16
0.586 / 14.88
0.826 / 20.97
0.938 / 23.82
411 / 611
247 / 112

18.1 / 460
23622U160800700
8
16
0.654 / 16.62
0.894 / 22.72
1.007 / 25.57
494 / 735
330 / 150
23622U161200700 19.9 / 506
12
16
0.791 / 20.09
0.995 / 25.27
1.107 / 28.12
638 / 950
494 / 224

21.5 / 547
23622U161600700
16
16
0.88 / 22.36
1.084 / 27.54
1.196 / 30.38
767 / 1141
659 / 299
23622U162400700 25.7 / 652
24
16
1.111 / 28.21
1.315 / 33.39
1.426 / 36.23
1076 / 1601
989 / 449

28.6 / 728
23622U163600700
36
16
1.276 / 32.4
1.48 / 37.58
1.592 / 40.43
1431 / 2130
1483 / 673

23621U180100700 10.7 / 272
1
18
0.243 / 6.17
0.483 / 12.27
0.595 / 15.11
145 / 215
26 / 12
12.9 / 328
23622U180200700
2
18
0.366 / 9.3
0.606 / 15.39
0.718 / 18.24
215 / 320
52 / 24

23622U180400700 14.3 / 364
4
18
0.444 / 11.27
0.684 / 17.37
0.796 / 20.21
278 / 414
104 / 47

15.8 / 401
23622U180600700
6
18
0.525 / 13.35
0.765 / 19.44
0.877 / 22.29
346 / 514
156 / 71
23622U180800700 16.6 / 421
8
18
0.568 / 14.42
0.808 / 20.52
0.92 / 23.37
394 / 586
208 / 94

19.1 / 484
23622U181200700
12
18
0.707 / 17.95
0.947 / 24.04
1.059 / 26.89
523 / 779
312 / 142
23622U181800700
20.6 / 522
18
18
0.827 / 21
1.031 / 26.18
1.143 / 29.02
666 / 991
468 / 212

1.303 / 33.1
23622U182400700
24
18
0.987 / 25.08
1.191 / 30.26
847 / 1260
624 / 283
23.5 / 596

23622U183600700
36
18
1.131 / 28.73
1.335 / 33.91
1.447 / 36.75
1112 / 1654
936 / 425
26 / 662

1 800 668 4842