Page 46 - ShawFlex.com | UL Catalogue
P. 46


UL XHHW-2


V.2 | 46




XHHW-2 | SINGLE CONDUCTOR (600V) 
PAGE 1 OF 1



For use in open wiring and raceways (with the exception of cable troughs and ventilated 

flexible cableways) in dry or wet locations. For open wiring exposed to the weather. Maximum 
conductor temperature 90°C.



Voltage
Certifications/Compliances
600V
• UL 44, Thermoset Insulated Wires and Cables 

Optional: 2000V
• CT Use (1/0 and larger)
12
• - 40°C cold bend rated
Product Construction
Colour Coding
1. Strand Bare (ASTM B8) Annealed Copper 
• Insulation:
Conductors
• Black conductor (standard)
2.
FR XLPE (XHHW-2/VW-1 Rated) Insulated -
FR XLPE (XHHW-2/ VW-1 rated) (standard) 
rated: 90°C wet/dry
Conductor
FR XLPE (RHW-2 rated) (optional) -

• Available in:
-
All colours




Part Number
NumberofConductors
Conductor Size InsulationThickness CableWeight(lbs/1000ft)/ Ampacity Max. Pulling Tension Min. Bend Radius (Pull) 
(AWG/MCM)
(in/mm)
(kg/km)
(30°C ambient)
(Pulling Eye) (lb/kg)
(in/mm)

1V010U14010BN00
1
14
0.03 / 0.76
18 / 27
35
33 / 15
1.2 / 30
1.4 / 35
1V010U12010BN00
1
12
0.03 / 0.76
27 / 40
40
52 / 24

1.6 / 40
1V010U10010BN00
1
10
0.03 / 0.76
40 / 59
55
83 / 38

2.1 / 54
1V010U08010BN00
1
8
0.045 / 1.14
68 / 101
80
132 / 60
2.4 / 62
1V010U06010BN00
1
6
0.045 / 1.14
101 / 151
105
210 / 95

2.9 / 73
1V010U04010BN00
1
4
0.045 / 1.14
154 / 230
140
334 / 151

3.4 / 86
1V010U02010BN00
1
2
0.045 / 1.14
237 / 352
190
531 / 241

3.9 / 100
1V010U01014BN00
1
1
0.055 / 1.4
300 / 447
220
670 / 304
4.3 / 109
1V010U1/014BN00
1
1/0
0.055 / 1.4
374 / 556
260
845 / 383

4.7 / 119
1V010U2/014BN00
1
2/0
0.055 / 1.4
464 / 691
300
1065 / 483

5.1 / 130
1V010U3/014BN00
1
3/0
0.055 / 1.4
579 / 861
350
1336 / 606
5.6 / 143 1V010U4/014BN00 1
4/0
0.055 / 1.4
722 / 1074
405
1693 / 768

6.2 / 158
1V010U25016BN00
1
250
0.065 / 1.65
845 / 1257
455
2000 / 907

1V010U35016BN00
1
350
0.065 / 1.65
1166 / 1735
570
2800 / 1270
7.2 / 182

1V010U50016BN00
1
500
0.065 / 1.65
1644 / 2446
700
4000 / 1814
8.3 / 211
1V010U75016BN00
1
750
0.08 / 2.03
2466 / 3670
885
6000 / 2722
10.2 / 259


*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(17). Values are corrected according to Table 310.15(B)(17) for number of Conductors.