Page 40 - ShawFlex.com | UL Catalogue
P. 40


UL TRAY


V.2 | 40



TC
CTS UTILITY | MULTI-CONDUCTOR (600V) 
PAGE 1 OF 2 



ShawFlex Utility cables are the ideal choice for applications requiring an extra level of durability and noise 

protection in utility applications.




Voltage
Certifications/Compliances
600V
• UL 1277, Tray Cable (TC-ER)

Optional: 300/2000V
• UL 44, Thermoset Insulated Wires and Cables 
• UL1685FT4,VerticalTrayFlameTestrated
1 2
3 4 5
Product Construction
• IEEE 1202/383 (70,000 BTU/hr), Vertical
• Insulation:
Flame Test rated (optional)

- FR XLPE (XHHW-2 rated)
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame
rated: 90°C wet/dry
Test rated
- VW-1 rated (optional)
• XLPE (XHHW-2 rated), 90°C wet/dry
1. Stranded Bare (ASTM B8) Annealed Copper 
• UV sunlight resistant “SUN RES” (all colours) Conductors (Tinned Available)
• Shielding:
2. FR XLPE (XHHW-2 Rated) Insulated Conductors 
• Direct burial rated
- Copper tape shield (standard)
3. Bare/Tinned Copper Tape Shield
• -40°C cold bend rated
-
Available in various copper tape thickness &
• Rated for use in hazardous locations:
4. Thermoset CPE Outer Protective Jacket
configurations 
- Class I Zone 2 (Div 2)
• Jacket:
- Class II Zone 22 (Div 2)
-
FR PVC outer black jacket 
rated: 90°C to -40°C
Colour Coding
- Thermoset CPE optional) 

• Method K1 & K2 (standard) -
Thermoplastic CPE (optional) 
• Method 4 (optional)
Thermoplastic LSZH (optional)
-
Available in:
- Custom insulation/jacket colors 

-
Composite constructions

Each utility has its own unique speci cations. Please contract ShawFlex for product details


Number of Conductor Size Nominal Diameter CableWeight(lbs/1000ft)/ Ampacity Max. Pulling Tension Min. Bend Radius (Pull)
Part Number Conductors (AWG/MCM) Overall Cable (kg/km) (30°C ambient) (Pulling Eye) (lb/kg) (in/mm) 
(in/mm)

2C01HU140200700 2 14 0.396 / 10.06 104 / 155 25 66 / 30 7.1 / 181
2C01HU140300700 3 14 0.416 / 10.57 123 / 184 25 99 / 45 7.5 / 190

2C01HU140400700 4 14 0.451 / 11.44 148 / 221 20 132 / 60 8.1 / 206

2C01HU140500700 5 14 0.489 / 12.42 171 / 255 20 165 / 75 8.8 / 224

2C01HU140600700 6 14 0.529 / 13.44 199 / 295 20 197 / 90 9.5 / 242
2C01HU140700700 7 14 0.529 / 13.44 212 / 316 17.5 230 / 104 9.5 / 242

2C01HU140800700 8 14 0.599 / 15.21 257 / 382 17.5 263 / 119 10.8 / 274

2C01HU141000700 10 14 0.692 / 17.58 319 / 474 12.5 329 / 149 12.5 / 316
2C01HU141200700 12 14 0.712 / 18.08 356 / 530 12.5 395 / 179 12.8 / 326

2C01HU141400700 14 14 0.746 / 18.96 401 / 597 12.5 461 / 209 13.4 / 341

2C01HU141500700 15 14 0.765 / 19.44 423 / 629 12.5 494 / 224 13.8 / 350

2C01HU142000700 20 14 0.905 / 22.98 571 / 849 12.5 658 / 298 16.3 / 414
2C01HU142500700 25 14 0.998 / 25.35 686 / 1021 11.25 823 / 373 18 / 456

2C01HU143000700 30 14 1.053 / 26.73 783 / 1166 11.25 987 / 448 18.9 / 481

2C01HU144000700 40 14 1.171 / 29.74 990 / 1474 10 1316 / 597 21.1 / 535

2C01HU145000700 50 14 1.296 / 32.92 1202 / 1789 8.75 1645 / 746 23.3 / 592
2C01HU120200700 2 12 0.432 / 10.97 130 / 194 30 104 / 47 7.8 / 198

2C01HU120300700 3 12 0.455 / 11.55 159 / 237 30 157 / 71 8.2 / 208

2C01HU120400700 4 12 0.494 / 12.55 192 / 285 24 209 / 95 8.9 / 226

2C01HU120500700 5 12 0.568 / 14.42 245 / 364 24 261 / 118 10.2 / 260
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(3)(a) for number of Conductors.



1 800 668 4842 shawcor.com
Pleasenote:Althoughthecontentusedforthisbrochurehasbeenproducedandprocessedfromsourcesbelievedtobereliable,nowarranty,expressedorimplied,ismaderegardingaccuracy,adequacy,completeness,legality,reliabilityorusefulnessofanyinformation

   38   39   40   41   42