Page 33 - ShawFlex.com | UL Catalogue
P. 33


UL METAL CLAD


V.2 | 33




AIA POWER | MULTI-CONDUCTOR (2000V) 
PAGE 2 OF 2




Number of Conductor Size GroundWireSize Nominal Diameter Nominal Diameter Cable Weight (lb- Ampacity Max.PullingTension Min. Bend Radius
Part Number
Conductors (AWG/MCM) (AWG/MCM)
Over Armor
Overall Cable s/1000ft)/(kg/km) (30°C ambient) (PullingEye)(lb/kg)
(Pull) 
(in/mm)
(in/mm)

2K610U120300709 3 12 12 0.715 / 18.15 14.9 / 378 0.827 / 21 310 / 461 30 157 / 71 

2K610U100300709 3 10 10 0.77 / 19.57 15.9 / 403 0.882 / 22.41 383 / 569 40 249 / 113 
2K610U080300709 3 8 10 0.879 / 22.34 17.8 / 453 0.991 / 25.18 491 / 731 55 397 / 180 

2K610U060300709 3 6 8 0.966 / 24.54 19.4 / 493 1.078 / 27.38 639 / 951 75 629 / 285 

2K610U040300709 3 4 8 1.005 / 25.54 20.1 / 511 1.117 / 28.38 823 / 1225 95 1002 / 454 
2K610U030300709 3 3 6 1.063 / 27.01 21.2 / 537 1.175 / 29.86 987 / 1468 115 1263 / 573 

2K610U020300709 3 2 6 1.13 / 28.7 22.4 / 568 1.242 / 31.55 1153 / 1715 130 1593 / 723 

2K610U010340709 3 1 6 1.3 / 33.02 25.4 / 646 1.412 / 35.86 1429 / 2127 145 2009 / 911 

2K610U1/0340709 3 1/0 6 1.386 / 35.2 27 / 685 1.498 / 38.05 1692 / 2517 170 2534 / 1150 
2K610U2/0340709 3 2/0 6 1.478 / 37.55 28.6 / 727 1.59 / 40.4 2011 / 2993 195 3194 / 1449 

2K610U3/0340709 3 3/0 4 1.588 / 40.34 31 / 786 1.72 / 43.69 2488 / 3702 225 4007 / 1818 

2K610U4/0340709 3 4/0 4 1.708 / 43.39 33.1 / 841 1.84 / 46.75 2983 / 4439 260 5078 / 2304 

2K610U250360709 3 250 4 1.973 / 50.11 37.9 / 962 2.105 / 53.46 3645 / 5425 290 6000 / 2722 
2K610U300360709 3 300 3 2.087 / 53 39.9 / 1014 2.219 / 56.36 4240 / 6309 320 7200 / 3266 

2K610U350360709 3 350 3 2.194 / 55.74 41.9 / 1064 2.326 / 59.09 4796 / 7137 350 8400 / 3810 

2K610U500360709 3 500 3 2.469 / 62.73 47.4 / 1203 2.632 / 66.84 6513 / 9693 430
12000 / 5443 
2K610U750360709 3 750 0 2.919 / 74.14 55.5 / 1409 3.081 / 78.25 9186 / 13671 535 18000 / 8165 

2K610U140400709 4 14 14 0.723 / 18.36 15 / 382 0.835 / 21.2 295 / 438 20 132 / 60

2K610U120400709 4 12 12 0.767 / 19.49 15.8 / 402 0.879 / 22.33 360 / 536 24 209 / 95 

2K610U100400709 4 10 10 0.829 / 21.06 16.9 / 430 0.941 / 23.91 452 / 672 32 332 / 151 
2K610U080400709 4 8 10 0.951 / 24.15 19.1 / 486 1.063 / 27 589 / 877 44 529 / 240 

2K610U060400709 4 6 8 1.01 / 25.67 20.2 / 513 1.122 / 28.51 763 / 1136 60
839 / 380 

2K610U040400709 4 4 8 1.127 / 28.63 22.3 / 567 1.239 / 31.47 1028 / 1530 76 1336 / 606 
2K610U030400709 4 3 6 1.194 / 30.33 23.5 / 597 1.306 / 33.17 1222 / 1819 92 1684 / 764 

2K610U020400709 4 2 6 1.271 / 32.28 24.9 / 632 1.383 / 35.13 1440 / 2143 104 2124 / 964 

2K610U010440709 4 1 6 1.431 / 36.36 27.8 / 706 1.543 / 39.2 1804 / 2684 116 2678 / 1215 

2K610U1/0440709 4 1/0 6 1.528 / 38.81 29.9 / 759 1.66 / 42.16 2178 / 3241 136 3379 / 1533 
2K610U2/0440709 4 2/0 6 1.631 / 41.44 31.7 / 806 1.763 / 44.79 2594 / 3860 156 4259 / 1932 

2K610U3/0440709 4 3/0 4 1.754 / 44.56 34 / 862 1.886 / 47.91 3161 / 4704 180 5343 / 2423 

2K610U4/0440709 4 4/0 4 1.99 / 50.55 38.2 / 970 2.122 / 53.91 4006 / 5961 208 6771 / 3071 

2K610U250460709 4 250 4 2.173 / 55.21 41.5 / 1054 2.305 / 58.56 4640 / 6905 232 8000 / 3629 
2K610U300460709 4 300 3 2.301 / 58.45 44.3 / 1126 2.463 / 62.57 5488 / 8166 256 9600 / 4355 

2K610U350460709 4 350 3 2.422 / 61.51 46.5 / 1181 2.584 / 65.63 6218 / 9253 280 11200 / 5080 

2K610U500460709
4 500 3
2.73 / 69.35
52.1 / 1322
2.892 / 73.46
8387 / 12481 344
16000 / 7258
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(16). Per NEC 310.15(B)(3)(a), the ampacity of 4/C cable shall be reduced by a factor of 0.8 

when the neutral is considered a currrent-carrying conductor.