Page 24 - ShawFlex.com | UL Catalogue
P. 24


UL METAL CLAD


V.2 | 24




ARMORED INSTRUMENTATION | PAIRS & TRIADS (600V) 
PAGE 1 OF 2



Metal Clad Armored Instrumentation cables can be used to minimize noise and signal 

interference by preventing crosstalk between pairs and triads. This cable can also be used to 
convert analogue or digital signals. Tray Instrumentation cables can be installed in raceways, 
direct burial applications and in outdoor exposed industrial applications.


Voltage
Certifications/Compliances

600V
• UL 1569, Metal Clad Cables (MC)
4
6
• UL 44, Thermoset Insulated Wires and Cables 
Product Construction
• UL 1685/FT4, Vertical Tray Flame Test rated
1
2
3
5
7 8 9
• Insulation:
• IEEE 1202/383 (70,000 BTU/hr), Vertical
- FR XLPE (XHHW-2 rated)
Flame Test rated
rated: 90°C wet/dry
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame
- VW-1 rated (optional)
1. Stranded Bare Copper Conductors (Tinned Available) 
• Armor:
Test rated 
• XLPE (XHHW-2 rated), 90°C wet/dry 2. FR XLPE (XHHW-2 Rated) Insulated Conductors 
• UV sunlight resistant “SUN RES” (all colours) (for 3.
- Aluminum Interlocked Armor (AIA) (standard)
Individual Shield & Overall Shielded Pairs/Triads 
CT use) 4. - Steel Interlocked Armor (SIA) (optional) Polypropylene Fillers
- Served Wire Armor (SWA) (optional)
• Direct burial rated 5. Polyester Separator Tape
• -40°C cold bend rated 6. -
Overall Aluminum/Mylar Shield with Tinned Copper Zetabon (optional) 
• Rated for use in hazardous locations:
Drain Wire
• Jacket:
- Class I Zone 2 (Div 2) 7. -
FR PVC Inner Protective Jacket
FR PVC outer black jacket 
rated: 90°C to -40°C
- Class II Zone 22 (Div 2) 8.
Aluminum Interlocked Armor (AIA)
9.
- FR PVC Outer Protective Jacket
Thermoset CPE optional) 
Colour Coding -
Thermoplastic CPE (optional) 
Thermoplastic LSZH (optional)
-
• Pairs - Black, & white, with black printing on 
• Available in:
white (standard)
•
Triads - Black, white & red, with black printing - Custom insulation/jacket colours 
on white (standard)
- Composite constructions






PAIRS



OD Over Cable Weight Min. Bend Radius Normal Diameters
Number of Conductor Size Inner Jacket (lbs/1000ft)/ (Pull) Max. Pulling Tension Part Number
Pairs
(AWG/MCM)
(Pulling Eye) (lb/kg)
Over Armour Overall Cable 
(in/mm)
(kg/km)
(in/mm)
(in/mm)
(in/mm)

2C621U160100700
0.337 / 8.56
0.577 / 14.66
0.689 / 17.5
41 / 19
12.4 / 315
1
16
194 / 288

2C622U160200700
15.4 / 392
2
16
0.504 / 12.81
0.744 / 18.91
300 / 446
82 / 37
0.856 / 21.75

17.6 / 447
2C622U160400700
4
16
0.627 / 15.92
0.866 / 22.01
0.978 / 24.85
401 / 597
165 / 75
2C622U160600700 19.6 / 498
6
16
0.736 / 18.7
0.976 / 24.8
1.088 / 27.64
511 / 761
247 / 112

21.3 / 540
2C622U160800700
8
16
0.865 / 21.97
1.069 / 27.15
1.181 / 30
612 / 911
330 / 150
2C622U161200700 23.4 / 593
1.298 / 32.97
12
16
0.982 / 24.93
1.186 / 30.12
783 / 1166
494 / 224

25.5 / 647
2C622U161600700
16
16
1.1 / 27.94
1.304 / 33.12
1.416 / 35.97
946 / 1408
659 / 299

2C622U162400700 30.9 / 784
24
16
1.378 / 35.01
1.582 / 40.19
1.714 / 43.55
1342 / 1997
989 / 449
34.8 / 884
2C622U163600700
36
16
1.597 / 40.57
1.801 / 45.75
1.933 / 49.1
1800 / 2679
1483 / 673

2C621U180100700 12 / 304
1
18
0.313 / 7.95
0.553 / 14.05
0.665 / 16.89
176 / 261
26 / 12

14.7 / 373
2C622U180200700
2
18
0.465 / 11.81
0.705 / 17.9
0.817 / 20.74
263 / 392
52 / 24
2C622U180400700 16.7 / 425
4
18
0.577 / 14.66
0.817 / 20.76
0.929 / 23.6
343 / 511
104 / 47

18.5 / 470
2C622U180600700
6
18
0.676 / 17.17
0.916 / 23.27
1.028 / 26.11
428 / 638
156 / 71
2C622U180800700 19.9 / 507
8
18
0.792 / 20.12
0.996 / 25.3
1.108 / 28.14
505 / 752
208 / 94

21.8 / 555
2C622U181200700
12
18
0.897 / 22.79
1.101 / 27.97
1.213 / 30.82
631 / 939
312 / 142

2C622U181800700
24.8 / 630
18
18
1.062 / 26.98
1.266 / 32.16
1.378 / 35
821 / 1222
468 / 212
2C622U182400700
24
18
1.255 / 31.88
1.459 / 37.07
1.571 / 39.91
1024 / 1525
624 / 283
28.3 / 718

2C622U183600700
36
18
1.452 / 36.89
1.656 / 42.07
1.788 / 45.42
1387 / 2064
936 / 425
32.2 / 818


1 800 668 4842
shawcor.com
Pleasenote:Althoughthecontentusedforthisbrochurehasbeenproducedandprocessedfromsourcesbelievedtobereliable,nowarranty,expressedorimplied,ismaderegardingaccuracy,adequacy,completeness,legality,reliabilityorusefulnessofanyinformation