Page 22 - ShawFlex.com | UL Catalogue
P. 22


UL TRAY


V.2 | 22



TC
POWER | MULTI-CONDUCTOR (2000V) 
PAGE 1 OF 2 



Tray Power cables are suitable for use in ventilated, non-ventilated and ladder type cable 

trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry 
locations in -40°C (-40°F) environments. Applicable for use in Utilities, Industrial and 
Commercial applications.


Voltage
Certifications/Compliances

2000V
• UL 1277, Tray Cable (TC) (optional)CPE & LSZH 
only)

Product Construction
• UL 44, Thermoset Insulated Wires and Cables 1 2 3 4 5
• Insulation:
• UL 1685/FT4, Vertical Tray Flame Test rated
- FR XLPE (RHW-2 rated)
• IEEE 1202/383 (70,000 BTU/hr), Vertical
rated: 90°C wet/dry Flame Test rated (optional)

• Jacket:
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame
1. Strand Bare (ASTM B8) Annealed Copper Conductors 
Test rated
2. FR XLPE (RHW-2 Rated) Insulated Conductors -
FR PVC outer black jacket 
• XLPE (RHW-2 rated), 90°C wet/dry
3. Polypropylene Fillers
rated: 90°C to -40°C
• UV sunlight resistant “SUN RES” (all colours) 4. Polyester Separator Tape
- Thermoset CPE (optional) 
• Direct burial rated
5. FR PVC Outer Protective Jacket
- Thermoplastic CPE (optional) 
• -40°C cold bend rated
-
Thermoplastic LSZH (optional)
• Rated for use in hazardous locations:
• Available in:
- Class I Zone 2 (Div 2)
- Custom insulation/jacket colors 
- Class II Zone 22 (Div 2)
- Composite constructions

Colour Coding

• Black conductors (standard)
• Optional:
- Method1 K1 or K2






Conductor Size NominalDiameterOverall CableWeight(lbs/1000ft)/ Ampacity Max. Pulling Tension Min. Bend Radius (Pull)
Part Number NumberofConductors (AWG/MCM) Cable (kg/km) (30°C ambient) (Pulling Eye) (lb/kg) (in/mm) 
(in/mm)

2K010U140200700 2 14 0.492 / 12.5 111 / 165 25 66 / 30 4.4 / 112
2K010U120200700 2 12 0.528 / 13.41 136 / 202 30 104 / 47 4.8 / 121

2K010U100200700 2 10 0.608 / 15.44 191 / 284 40 166 / 75 5.5 / 139

2K010U080200700 2 8 0.706 / 17.93 261 / 388 55 265 / 120 6.4 / 161

2K010U060200700 2 6 0.784 / 19.91 346 / 516 75 419 / 190 7.1 / 179
2K010U040200700 2 4 0.918 / 23.32 513 / 764 95 668 / 303 8.3 / 210

2K010U030200700 2 3 0.972 / 24.69 608 / 904 115 842 / 382 8.7 / 222

2K010U020200700 2 2 1.034 / 26.26 718 / 1069 130 1062 / 482 9.3 / 236

2K010U010240700 2 1 1.192 / 30.28 915 / 1362 145 1339 / 607 10.7 / 272
2K010U1/0240700 2 1/0 1.272 / 32.31 1100 / 1637 170 1690 / 766 11.4 / 291

2K010U2/0240700 2 2/0 1.358 / 34.49 1321 / 1966 195 2130 / 966 12.2 / 310

2K010U3/0240700 2 3/0 1.46 / 37.08 1594 / 2372 225 2671 / 1212 13.1 / 334
2K010U4/0240700 2 4/0 1.572 / 39.93 1932 / 2876 260 3386 / 1536 14.1 / 359

2K010U250260700 2 250 1.784 / 45.31 2366 / 3520 290 4000 / 1814 16.1 / 408

2K010U300260700 2 300 1.89 / 48.01 2754 / 4099 320 4800 / 2177 17 / 432

2K010U350260700 2 350 1.99 / 50.55 3138 / 4670 350 5600 / 2540 17.9 / 455
2K010U500260700 2 500 2.246 / 57.05 4259 / 6338 430 8000 / 3629 20.2 / 513

2K010U140300700 3 14 0.521 / 13.23 137 / 204 25 99 / 45 4.7 / 119

2K010U120300700 3 12 0.59 / 14.98 189 / 282 30 157 / 71 5.3 / 135
*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(16).




1 800 668 4842
shawcor.com
Pleasenote:Althoughthecontentusedforthisbrochurehasbeenproducedandprocessedfromsourcesbelievedtobereliable,nowarranty,expressedorimplied,ismaderegardingaccuracy,adequacy,completeness,legality,reliabilityorusefulnessofanyinformation

   20   21   22   23   24