Page 18 - ShawFlex.com | UL Catalogue
P. 18


UL TRAY


V.2 | 18



TC
POWER | MULTI-CONDUCTOR (600V) 
PAGE 1 OF 2 



Tray Power cables are suitable for use in ventilated, non-ventilated and ladder type cable 

trays, direct burial, raceways and for exposed or concealed wiring in wet, damp or dry 
locations in -40°C (-40°F) environments. Applicable for use in Utilities, Industrial and 
Commercial applications.


Voltage
Certifications/Compliances

600V
• UL 1277, Tray Cable (TC-ER)
• UL 44, Thermoset Insulated Wires and Cables 
Product Construction
• UL 1685/FT4, Vertical Tray Flame Test rated
1 2 3 4 5
• Insulation:
• IEEE 1202/383 (70,000 BTU/hr), Vertical
- FR XLPE (XHHW-2 rated)
Flame Test rated (optional)
rated: 90°C wet/dry
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame

- VW-1 rated (optional)
Test rated
1. Strand Bare (ASTM B8) Annealed Copper Conductors 
• Armor:
• XLPE (XHHW-2 rated), 90°C wet/dry
2. FR XLPE (XHHW-2 Rated) Insulated Conductors 
- Zetabon (optional)
• UV sunlight resistant “SUN RES” (all colours) 3. Polypropylene Fillers
• Jacket:
• Direct burial rated
4. Polyester Separator Tape

• -40°C cold bend rated
5. FR PVC Outer Protective Jacket
-
FR PVC outer black jacket 
• Rated for use in hazardous locations:
rated: 90°C to -40°C
- Class I Zone 2 (Div 2)
- Thermoset CPE (optional) 
- Class II Zone 22 (Div 2)
- Thermoplastic CPE (optional) 

Colour Coding
-
Thermoplastic LSZH (optional)
• Available in:
• Black conductors (standard) - Custom insulation/jacket colors 
• Optional:
- Composite constructions
- Method1 K1 or K2




NominalDiameterOverall 
Number of Conductor Size CableWeight(lbs/1000ft)/ Ampacity Max. Pulling Tension Min. Bend Radius (Pull)
Part Number Cable 
Conductors (AWG/MCM) (kg/km) (30°C ambient) (Pulling Eye) (lb/kg) (in/mm) (in/mm)

2C010U140200700 2 14 0.372 / 9.45 72 / 108 25 66 / 30 3.3 / 85

2C010U120200700 2 12 0.408 / 10.36 95 / 141 30 104 / 47 3.7 / 93

2C010U100200700 2 10 0.458 / 11.63 128 / 191 40 166 / 75 4.1 / 105
2C010U080200700 2 8 0.606 / 15.39 218 / 324 55 265 / 120 5.5 / 139

2C010U060200700 2 6 0.684 / 17.37 298 / 443 75 419 / 190 6.2 / 156

2C010U040200700 2 4 0.778 / 19.76 426 / 634 95 668 / 303 7 / 178
2C010U030200700 2 3 0.832 / 21.13 511 / 761 115 842 / 382 7.5 / 190

2C010U020200700 2 2 0.934 / 23.72 656 / 977 130 1062 / 482 8.4 / 214

2C010U010240700 2 1 1.052 / 26.72 816 / 1214 145 1339 / 607 9.5 / 240

2C010U1/0240700 2 1/0 1.132 / 28.75 991 / 1474 170 1690 / 766 10.2 / 259
2C010U2/0240700 2 2/0 1.218 / 30.94 1202 / 1789 195 2130 / 966 11 / 278

2C010U3/0240700 2 3/0 1.32 / 33.53 1468 / 2184 225 2671 / 1212 11.9 / 302

2C010U4/0240700 2 4/0 1.432 / 36.37 1799 / 2677 260 3386 / 1536 12.9 / 327
2C010U250260700 2 250 1.564 / 39.73 2099 / 3123 290 4000 / 1814 14.1 / 358

2C010U300260700 2 300 1.67 / 42.42 2465 / 3668 320 4800 / 2177 15 / 382

2C010U350260700 2 350 1.83 / 46.48 2939 / 4373 350 5600 / 2540 16.5 / 418

2C010U500260700 2 500 2.086 / 52.98 4036 / 6007 430 8000 / 3629 18.8 / 477
2C010U140300700 3 14 0.392 / 9.96 90 / 134 25 99 / 45 3.5 / 90

2C010U120300700 3 12 0.431 / 10.94 122 / 182 30 157 / 71 3.9 / 98

*Ampacity value based on National Electrical Code, Version 2017, Table 3-10.15(B)(16).