Page 13 - ShawFlex.com | UL Catalogue
P. 13


UL PLTC


V.2 | 13



TC
TRAY FIELDBUS/PROFIBUS PA | PAIRS (300) 
PAGE 1 OF 1 



Fieldbus is the Process Industries digital replacement for analog 4-20mA transmission of process 

variables. Depending mainly on the current requirement of each device, up to 32 sensors and 
actuators are possible on a Fieldbus link with a maximum transmission distance of 1900m.

Voltage
Certifications/Compliances

300V
• UL 1277, Tray Cable (TC-ER) (optional)
• Foundation Fieldbus Spec. FF-844, Type “A”,H1 
Product Construction
• UL 13, Power Limited Tray Cable (PLTC)
• Insulation:
• UL 2250, Instrumentation Tray Cable (ITC)

- FR XLPE (VW-1 rated)
• UL 44, Thermoset Insulated Wires and Cables) 
rated: 60°C wet/105°C dry
• UL 1685/FT4, Vertical Tray Flame Test rated
• Shielding (foil-free edge):
• IEEE 1202/383 (70,000 BTU/hr), Vertical
- ISOS (standard)
Flame Test rated

- OS (optional)
• ICEA T-30-520 (70,000 BTU/hr), Vertical Flame
123 4
• Armor:
Test rated
- Braided Armor for Shipboard ABS approval
• XLPE (TW 75 rated), 90°C wet/ 105°C dry 
(optional)
• UV sunlight resistant “SUN RES” (all colours) 
1. Stranded Tinned Copper Pairs
• Jacket:
• Direct burial rated
2. FR XLPE (VW-1 Rated) Insulated Pairs
• -40°C cold bend/impact rated
(standard)
-
FR PVC outer orange jacket (standard for 
• Rated for use in hazardous locations:
3. Individual Aluminum/Mylar Shield with Drain
Fieldbus)
- Class I Zone 0 (Intrinsically Safe cables only) rated: 90°C to -40°C
Wire Over Each Pair
- Class I Zone 2 (Div 2)
4. FR PVC Outer Protective Jacket
-
FR PVC outer purple jacket (standard for Profibus) 
rated: 90°C to -40°C
- Black with integral orange stripe (optional) 
Colour Coding
- Blue for Intrinsically Safe applications
• Blue and Orange conductors (standard)
- Thermoset CPE (optional) 
- Thermoplastic CPE (optional) 
-
Thermoplastic LSZH (optional)

• Available in:
- Custom insulation/jacket colors









Conductor Size NominalDiameterOverall Cable Weight (lb- Max. Pulling Tension Min. Bend Radius (Pull) 
Part Number
(AWG/MCM)
Cable (in/mm)
s/1000ft)/(kg/km)
(Pulling Eye) (lb/kg)
(in/mm)
Number of Pairs


2F021U160105700
1
16
0.357 / 9.07
66 / 98
41 / 19
6.4 / 163

2F022U160205700 10 / 255
2
16
0.557 / 14.16
149 / 222
82 / 37

12.1 / 307
2F022U160405700
0.672 / 17.08
230 / 342
165 / 75
4
16
2F022U160605700 14.5 / 369
6
16
0.807 / 20.49
330 / 491
247 / 112

15.8 / 401
2F022U160805700
8
16
0.877 / 22.27
410 / 610
330 / 150

2F022U161205700 19.7 / 499
12
16
1.092 / 27.73
607 / 903
494 / 224
22 / 558
2F022U161605700
16
16
1.22 / 30.99
762 / 1134
659 / 299

2F022U162405700 27.7 / 705
24
16
1.541 / 39.14
1139 / 1695
989 / 449
5.6 / 143
2F021U180105700
1
18
0.313 / 7.95
49 / 73
26 / 12

2F022U180205700 8.7 / 222
2
18
0.485 / 12.31
111 / 165
52 / 24

10.2 / 258
2F022U180405700
4
18
0.564 / 14.33
157 / 233
104 / 47
2F022U180605700 12.5 / 318
6
18
0.696 / 17.68
236 / 351
156 / 71

13.6 / 345
2F022U180805700
8
18
0.754 / 19.16
291 / 432
208 / 94

2F022U181205700 16.9 / 429
12
18
0.937 / 23.81
425 / 633
312 / 142
19.8 / 504
2F022U181805700
18
18
1.102 / 27.99
593 / 882
468 / 212

2F022U182405700
23.7 / 601
24
18
1.315 / 33.41
793 / 1180
624 / 283




1 800 668 4842
shawcor.com
Pleasenote:Althoughthecontentusedforthisbrochurehasbeenproducedandprocessedfromsourcesbelievedtobereliable,nowarranty,expressedorimplied,ismaderegardingaccuracy,adequacy,completeness,legality,reliabilityorusefulnessofanyinformation