Page 8 - ShawFlex.com | Marine
P. 8

MARINE 



METRIC
V.2 | 8




IEC POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) 
PAGE 1 OF 2



ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard 
and marine applications. Our cables are made to IEC speciications and can be modiied to it 

your speciic requirements.

Voltage Certiications/Compliances

600/1000V
• IEC 60092-350
• IEC 60754-1
Product Construction
• IEC 61034-1&2

• Insulation:
• EC 60228 Class 5
35 
- Halogen Free XLPE (RW90 rated
• IEC 60092-353, Control & Power
rated: 90°C wet/dry, 60092-351
• IEC 60092-376, Instrumentation
1246
• Shield:
• IEC 60332-3-22, Category A Flame Propagate Testing 

- Aluminum/mylar foil shield with drain wire (optional)
• Lloyd’s Register
• Jacket:
• American Bureau of Shipping
1. High Stranded Bare Copper Conductors 
- LSZH Thermoplastic, black (standard) • Transport Canada
(Tinned Available)
rated: 75°C , SHF1 IEC 60092-359
• RoHS Compliant
2. Halogen Free XLPE (RW90 Rated) Insulated 

• Available in:
• UV sunlight resistant “SUN RES” (all colours) Conductors
- Custom insulation/jacket colours
• - 40°C cold bend rated
3. Polypropylene Fillers
• - 35°C cold impact rated
4. Fiberglass Tape

Colour Coding
5. Polyester Separator Tape 
6. Protective LSZH Jacket
• 2C – Brown, blue
• 3C – Brown, black, grey

• 4C – Brown, black, grey, blue 
• 5C & higher– Black # Coded

ShawFlex can manufacture up to 50 conductors in 0.75mm2, 1.5mm2, and 2.5mm2


Part Number Number of Conductors Cross Section (mm2)
Nominal OD Overall Cable Cable Weight (lbs/1000ft)/ Ampacity 
(in/mm) (kg/km) (45°C ambient)

SE010E3A02F0801 2 1.5 9.3 / 0.37 111 / 75 20

SE010E5A02F0801 2 2.5 10.1 / 0.4 138 / 93 22

SE010E0402F0801 2 4 11.8 / 0.47 197 / 132 30
SE010E0602F0801 2 6 13 / 0.51 247 / 166 39

SE010E1002F0801 2 10 14.5 / 0.57 339 / 228 54
SE010E1602F0801 2 16 17.7 / 0.7 518 / 348 73

SE010E2502F0801 2 25 21 / 0.83 752 / 506 97

SE010E3502F0801 2 35 23.8 / 0.94 983 / 661 128
SE010E5002F0801 2 50 26.9 / 1.06 1345 / 904 150

SE010E3A03F0801 3 1.5 9.7 / 0.38 132 / 89 16

SE010E5A03F0801 3 2.5 10.7 / 0.42 167 / 112 19
SE010E0403F0801 3 4 12.5 / 0.49 242 / 163 24

SE010E0603F0801 3 6 13.7 / 0.54 311 / 209 33
SE010E1003F0801 3 10 15.6 / 0.61 452 / 304 44

SE010E1603F0801 3 16 19 / 0.75 690 / 464 59

SE010E2503F0801 3 25 22.5 / 0.89 1015 / 683 80
SE010E3503F0801 3 35 25.5 / 1 1344 / 903 106

SE010E5003F0801 3 50 28.9 / 1.14 1845 / 1240 123

SE010E3A04F0801 4 1.5 10.6 / 0.42 158 / 106 16
SE010E5A04F0801 4 2.5 11.8 / 0.47 213 / 143 19

SE010E0404F0801 4 4 13.6 / 0.53 295 / 198 24
SE010E0604F0801 4 6 15.2 / 0.6 399 / 268 33

*Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors.



1 800 668 4842
shawlex.com

Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information


   6   7   8   9   10