Page 7 - ShawFlex.com | Marine
P. 7

MARINE 



METRIC
V.2 | 7




IEC POWER & CONTROL | SINGLE CONDUCTOR (600/1000V) 
PAGE 1 OF 1



ShawFlex IEC Power and Control cables are suitable for use in offshore oil and gas, shipboard 
and marine applications. Our cables are made to IEC speciications and can be modiied to it 
your speciic requirements.


Voltage
Certiications/Compliances

600/1000V
• IEC 60092-350
• IEC 60754-1
Product Construction
• IEC 61034-1&2

• Insulation:
• IEC60228 Class 5
- Halogen Free XLPE (RW90 rated)
• IEC 60092-353, Control & Power
123
rated: 90°C wet/dry, IEC 60092-351
• IEC 60092-376, Instrumentation
• Jacket:
• IEC60332-3-22,CategoryAFlamePropagateTesting 

- LSZH Thermoplastic, black (standard) • Lloyd’s Register
rated: 75°C , SHF1 IEC 60092-359
• American Bureau of Shipping
1. High Strand Bare Copper Conductors (Tinned 
• Available in:
• Transport Canada
Available)
- Custom insulation/jacket colours
• RoHS Compliant
2. Halogen Free XLPE (RW90 Rated) Insulated 
Conductors
• UV sunlight resistant “SUN RES” (all colours) 
• - 40°C cold bend rated
3. Protective LSZH Jacket
• - 35°C cold impact rated

Colour Coding

• Black conductor (standard)







Nominal OD Overall Cable Ampacity 
Part Number Number of Conductors Cross Section (mm2) Cable Weight (lbs/1000ft)/(kg/km) (in/mm) (45°C ambient)


SE010E3A01F0801 1 1.5 5.5 / 0.22 50 / 33 23

SE010E5A01F0801 1 2.5 5.9 / 0.23 62 / 42 26
SE010E0401F0801 1 4 6.6 / 0.26 83 / 56 35

SE010E0601F0801 1 6 7.2 / 0.28 105 / 70 47

SE010E1001F0801 1 10 8.2 / 0.32 152 / 102 64

SE010E1601F0801 1 16 9.7 / 0.38 226 / 152 85
SE010E2501F0801 1 25 11.5 / 0.45 332 / 223 114

SE010E3501F0801 1 35 12.7 / 0.5 427 / 287 152

SE010E5001F0801 1 50 14.2 / 0.56 580 / 390 176
SE010E7001F0801 1 70 16.8 / 0.66 793 / 533 204

SE010E9501F0801 1 95 18.7 / 0.74 1009 / 678 272

SE010E1C01F0801 1 120 20.7 / 0.81 1280 / 860 315

SE010E1D01F0801 1 150 22.4 / 0.88 1586 / 1066 357
SE010E1E01F0801 1 185 24.7 / 0.97 1924 / 1293 432

SE010E2C01F0801 1 240 27.1 / 1.07 2523 / 1695 541

SE010E3F01F0801 1 300 31 / 1.22 3100 / 2083 580

*Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors.











1 800 668 4842
shawlex.com

Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information