IEC INSTRUMENTATION | PAIRS & TRIADS (250V) 
PAGE 1 OF 1



ShawFlex IEC Instrumentation cables are suitable for use in offshore oil and gas, shipboard 
and marine applications. Our cables are made to IEC speciications and can be modiied to it 
your speciic requirements.


Voltage
Certiications/Compliances

250V
• IEC 60092-350
• IEC 60754-1
Product Construction
• IEC 61034-1&2

• Insulation:
• EC 60228 Class 5
5 
- XLPE (RW90 rated)
• IEC 60092-353, Control & Power
rated: 90°C wet/dry, 60092-351
• IEC 60092-376, Instrumentation
• Shielding:
• IEC 60332-3-22, Category A Flame Propagate
123467

- Aluminum/mylar foil shield with tinned Testing
copper drain wire (standard), available for • Lloyd’s Register
1. High Strand Bare Copper Conductors (Tinned 
both individual and overall shields
• American Bureau of Shipping
Available)
- Aluminum/mylar foil shield with drain wire • Transport Canada
2. Halogen Free XLPE (RW90 Rated) Insulated 
Conductors
(optional)
• RoHS Compliant
• Jacket:
• UV sunlight resistant “SUN RES” (all colours) 3. Fiberglass Tape
- LSZH Thermoplastic, black (standard)
• - 40°C cold bend rated
4. Polyester Separator Tape
rated: 75°C , SHF1 IEC 60092-359 • - 35°C cold impact rated
5. Overall Aluminum/Mylar Shield with Tinned
Copper Drain Wire 
• Available in:
- Custom insulation/jacket colours
Colour Coding
6. Protective LSZH Jacket
• Pairs - White, blue, # coded
• Triads - White, blue, red, # coded


ShawFlex can manufacture up to 50 components in 0.75mm2, 1.5mm2, and 2.5mm2


Nominal OD Overall Cable Ampacity 
Part Number Number of Pairs/Triads Cross Section (mm2) Cable Weight (lbs/1000ft)/(kg/km) (in/mm) (45°C ambient)


SF021E1B01F0801 1PR 0.75 6.8 / 0.27 70 / 47 15

SF022E1B02F0801 2PR 0.75 11.1 / 0.44 153 / 102 11

SF022E1B04F0801 4PR 0.75 13 / 0.51 227 / 153 8
SF022E1B08F0801 8PR 0.75 16.8 / 0.66 380 / 255 8

SF022E1B12F0801 12PR 0.75 20.5 / 0.81 541 / 363 8

SF022E1B16F0801 16PR 0.75 23 / 0.91 685 / 460 7
SF022E1B24F0801 24PR 0.75 28.3 / 1.12 1001 / 673 6

SF021E3A01F0801 1PR 1.5 8.5 / 0.34 104 / 70 20

SF022E3A02F0801 2PR 1.5 13.9 / 0.55 231 / 156 16

SF022E3A04F0801 4PR 1.5 16.3 / 0.64 353 / 237 11
SF022E3A08F0801 8PR 1.5 21.3 / 0.84 592 / 398 11

SF022E3A12F0801 12PR 1.5 26.3 / 1.04 870 / 585 11

SF022E3A16F0801 16PR 1.5 29.5 / 1.16 1102 / 741 10
SF022E3A24F0801 24PR 1.5 36.8 / 1.45 1646 / 1106 8

SF031E1B01F0801 1TRD 0.75 7.2 / 0.28 82 / 55 11

SF032E1B02F0801 2TRD 0.75 12.5 / 0.49 196 / 131 9

SF032E1B04F0801 4TRD 0.75 14.4 / 0.57 287 / 193 8
SF032E1B08F0801 8TRD 0.75 19 / 0.75 498 / 335 8

SF031E3A01F0801 1TRD 1.5 8.9 / 0.35 125 / 84 16

SF032E3A02F0801 2TRD 1.5 15.7 / 0.62 301 / 202 13
SF032E3A04F0801 4TRD 1.5 18.2 / 0.72 449 / 302 11

SF032E3A08F0801 8TRD 1.5 24.1 / 0.95 784 / 527 11

*Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors.