Page 21 - ShawFlex.com | Marine
P. 21


MARINE 


AWG
V.2 | 21




IEEE 1580 CONTROL | SINGLE CONDUCTOR (600/1000V) 
PAGE 1 OF 1



ShawFlex IEEE 1580 Control cables are suitable for use in offshore oil and gas, shipboard and 

marine applications. Our cables are made to IEC speciications and can be modiied to it your 
speciic requirements.


Voltage Certiications/Compliances
600/1000V
• IEEE 1580

Product Construction
• ASTM B8 (conductors)
• CSA FT4, Vertical Tray Flame Test rated 
• Insulation:
• IEC 60332-3-22, Category A Flame
- Halogen Free XLPE (RW90 rated)
Propagate Testing
123

• Jacket:
• American Bureau of Shipping
- FR PVC Outer Black Jacket
• Transport Canada
1. High Strand Bare Copper Conductors 
rated: 90°C (194°F) to -40°C (40°F) • RoHS Compliant
• Available in:
• UV sunlight resistant “SUN RES” (all colours) (Tinned Available)
2. Halogen Free XLPE (RW90 Rated) Insulated 
- Custom insulation/jacket colours
• - 40°C cold bend rated
Conductors
• - 35°C cold impact rated
3. FR PVC Outer Protective Jacket

Colour Coding

• Black conductors (standard)







Part Number Number of Conductors Cross Section Nominal OD Overall Cable Cable Weight (lbs/1000ft)/(kg/km) Ampacity 
(AWG/MCM)) (in/mm) (30°C ambient)

SY010M160100000 1 16 5.6 / 0.22 48 / 32 18

SY010M140100000 1 14 6 / 0.24 57 / 39 29

SY010M120100000 1 12 6.4 / 0.25 73 / 49 36

SY010M100100000 1 10 7.1 / 0.28 97 / 65 46
SY010M080100000 1 8 8.6 / 0.34 144 / 97 60

SY010M060100000 1 6 9.5 / 0.37 199 / 134 79

SY010M040100000 1 4 10.7 / 0.42 285 / 191 101
SY010M020100000 1 2 12.2 / 0.48 416 / 279 137

SY010M010140000 1 1 14.4 / 0.57 545 / 366 161

SY010M1/0140000 1 1/0 15.4 / 0.61 661 / 444 183

SY010M2/0140000 1 2/0 16.5 / 0.65 804 / 540 233
SY010M3/0140000 1 3/0 17.8 / 0.7 983 / 661 245

SY010M4/0140000 1 4/0 19.3 / 0.76 1206 / 811 284

SY010M250160000 1 250 20.9 / 0.82 1421 / 955 316
SY010M350160000 1 350 24.6 / 0.97 1986 / 1334 387

SY010M500160000 1 500 27.8 / 1.1 2740 / 1841 479

SY010M750160000 1 750 33.1 / 1.3 4028 / 2707 602

*Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors.













1 800 668 4842 shawlex.com