Page 13 - ShawFlex.com | Marine
P. 13


MARINE 


AWG
V.2 | 13




IEC INSTRUMENTATION | PAIRS & TRIADS (250V) 
PAGE 1 OF 1


ShawFlex IEC Instrumentation cables are suitable for use in offshore oil and gas, shipboard 

and marine applications. Our cables are made to IEC speciications and can be modiied to it 
your speciic requirements.


Voltage
Certiications/Compliances
250V
• IEC 60092-350

Product Construction
• IEC 60754-1
• IEC 61034-1&2
• Insulation:
• EC 60228 Class 5
5 
- XLPE (RW90 rated)
• IEC 60092-353, Control & Power
123467
RW90 rated: 90°C wet/dry, 60092-351
• IEC 60092-376, Instrumentation
• Shielding:
• IEC 60332-3-22, Category A Flame Propagate
- Aluminum/mylar foil shield with tinned Testing
copper drain wire (standard), available for • Lloyd’s Register
1. High Strand Bare Copper Conductors (Tinned 
both individual and overall shields
• American Bureau of Shipping
Available)
- Aluminum/mylar foil shield with drain wire • Transport Canada
2. XLPE (RW90 Rated) Insulated Conductors
(optional)
• RoHS Compliant
• Jacket:
• UV sunlight resistant “SUN RES” (all colours) 3. Fiberglass Tape
4. Polyester Separator Tape
- LSZH Thermoplastic, black (standard)
• - 40°C cold bend rated
5. Overall Aluminum/Mylar Shield with Tinned
rated: 75°C , SHF1 IEC 60092-359 • - 35°C cold impact rated
Copper Drain Wire
• Available in:
- Custom insulation/jacket colours
Colour Coding
6. Protective LSZH Jacket

• Pairs - White, blue, # coded
• Triads - White, blue, red, # coded



Part Number Number of Pairs/Triads Cross Section Nominal OD Overall Cable Cable Weight (lbs/1000ft)/(kg/km) Ampacity 
(AWG/MCM) (in/mm) (45°C ambient)


SF021U180100800 1PR 18 6.93 / 0.27 72 / 48 15
SF022U180200800 2PR 18 11.25 / 0.44 157 / 106 11

SF022U180400800 4PR 18 13.2 / 0.52 234 / 157 7.7

SF022U180800800 8PR 18 17.13 / 0.67 392 / 263 7.7

SF022U181200800 12PR 18 20.9 / 0.82 558 / 375 7.7

SF022U181600800 16PR 18 23.43 / 0.92 706 / 475 6.6
24PR 
SF022U182400800 18 28.89 / 1.14 1033 / 694 5.5
SF021U160100800 1PR 16 8.31 / 0.33 102 / 68 20

SF022U160200800 2PR 16 13.51 / 0.53 222 / 149 16

SF022U160400800 4PR 16 15.88 / 0.63 340 / 228 11.2

SF022U160800800 8PR 16 20.71 / 0.82 569 / 382 11.2

SF022U161200800 12PR 16 25.59 / 1.01 831 / 558 11.2
SF022U161600800 16PR 16 28.41 / 1.12 1034 / 695 9.6

SF022U162400800 24PR 16 35.43 / 1.4 1545 / 1039 8

SF031U180100800 1TRD 18 7.27 / 0.29 85 / 57 11

SF032U180200800 2TRD 18 12.7 / 0.5 202 / 136 8.8

SF032U180400800 4TRD 18 14.64 / 0.58 297 / 199 7.7
8TRD 
SF032U180800800 18 19.36 / 0.76 514 / 346 7.7
SF031U160100800 1TRD 16 8.72 / 0.34 121 / 81 16

SF032U160200800 2TRD 16 15.26 / 0.6 291 / 195 12.8

SF032U160400800 4TRD 16 17.67 / 0.7 430 / 289 11.2

SF032U160800800 8TRD 16 23.42 / 0.92 759 / 510 11.2

*Ampacity value based on National Electrical Code, Version 2011, Table 3-10.15(B)(16). Values are corrected according to Table 310.15(B)(16) for number of Conductors.

1 800 668 4842 shawlex.com

Please note: Although the content used for this brochure has been produced and processed from sources believed to be reliable, no warranty, expressed or implied, is made regarding accuracy, adequacy, completeness, legality, reliability or usefulness of any information


   11   12   13   14   15