IEC ARMOURED POWER & CONTROL | MULTI-CONDUCTOR (600/1000V) 
PAGE 1 OF 1



ShawFlex IEC Armoured Power and Control cables are suitable for use in offshore oil and gas, 

shipboard and marine applications. Our cables are made to IEC speciications and can be 
modiied to it your speciic requirements.

Voltage Certiications/Compliances

600/1000V
• IEC 60092-350
• IEC 60754-1
Product Construction
• IEC 61034-1&2 4 
• Insulation:
• IEC 60228 Class 5
123567
- XLPE (RW90 rated)
IEC 60092-353, Control & Power
rated: 90°C wet/dry, 60092-351 • IEC 60092-376, Instrumentation
• Armour:
• IEC 60332-3-22, Category A Flame Propagate Testing 
- Tinned copper braid (optional)
• Lloyd’s Register
1. High Strand Bare Copper Conductors 

- Bronze braid (optional)
• American Bureau of Shipping
(Tinned Available)
Jacket:
• Transport Canada
2. Halogen Free XLPE (RW90 Rated) Insulated 
- LSZH Thermoplastic, black (standard)
• RoHS Compliant
Conductors
rated: 75°C , SHF1 IEC 60092-359 • UV sunlight resistant “SUNRES” (all colours)
3. Polypropylene Fillers

• Available in:
• - 40°C cold bend rated
4. Fiberglass Tape
- Custom insulation/jacket colours
• - 35°C cold impact rated
5. Polyester Separator Tape
6. Tinned Copper Braided Armour 
Colour Coding
7. Protective LSZH Jacket
• 2C – Brown, blue
• 3C – Brown, black, grey
• 4C – Brown, black, grey, blue 

• 5C & higher– Black # Coded

ShawFlex can manufacture up to 50 conductors in 0.75mm2, 1.5mm2, and 2.5mm2

Nominal OD Overall Cable Ampacity 
Part Number Number of Conductors Cross Section (mm2) Cable Weight (lbs/1000ft)/(kg/km) (in/mm) (45°C ambient)


SEC10E3A02F08N9 2 1.5 10.1 / 0.4 164 / 110 20
SEC10E5A02F08N9 2 2.5 11.1 / 0.44 201 / 135 22

SEC10E0402F08N9 2 4 12.8 / 0.5 271 / 182 30

SEC10E0602F08N9 2 6 14.4 / 0.57 365 / 246 39
SEC10E1002F08N9 2 10 16.1 / 0.64 484 / 326 54

SEC10E1602F08N9 2 16 19.3 / 0.76 696 / 468 73

SEC10E2502F08N9 2 25 22.6 / 0.89 964 / 648 97
SEC10E3502F08N9 2 35 25.2 / 0.99 1211 / 813 128

SEC10E3A03F08N9 3 1.5 10.7 / 0.42 193 / 129 16
SEC10E5A03F08N9 3 2.5 11.9 / 0.47 243 / 164 19

SEC10E0403F08N9 3 4 13.5 / 0.53 321 / 216 24

SEC10E0603F08N9 3 6 15.4 / 0.61 448 / 301 33
SEC10E1003F08N9 3 10 17 / 0.67 594 / 399 44

SEC10E1603F08N9 3 16 20.4 / 0.8 865 / 581 59

SEC10E2503F08N9 3 25 23.9 / 0.94 1223 / 822 80
SEC10E3503F08N9 3 35 26.9 / 1.06 1586 / 1066 106

SEC10E3A04F08N9 4 1.5 11.8 / 0.47 234 / 157 16

SEC10E5A04F08N9 4 2.5 12.8 / 0.51 288 / 193 19
SEC10E0404F08N9 4 4 15.2 / 0.61 431 / 290 24

SEC10E0604F08N9 4 6 16.6 / 0.66 538 / 362 33
SEC10E1004F08N9 4 10 18.7 / 0.74 739 / 496 44

SEC10E1604F08N9 4 16 22.5 / 0.89 1080 / 726 59

*Ampacity value based on Canadian Electrical Code, Version 2012, Table-2. Values are corrected according to Table-5C for number of Conductors.